XGN66-12 Fixed Box-Type Metal-Clad Switchgear
GOHO XGN66-12 new-generation fixed enclosed box-type switchgear — 12kV compact metal-clad MV panel with ZN vacuum circuit breaker, disconnecting switch, and earthing switch in one enclosure. 630–3150A, 20–31.5kA, compact 800mm/1000mm width. Ideal for space-constrained substations, secondary distribution, and prefabricated substation integration.
New-Generation Compact Fixed Switchgear
Smaller footprint, simpler construction, same reliable performance — perfect for space-constrained installations.
Engineered for Compact Installations
The XGN66-12 is a new-generation fixed enclosed box-type high-voltage switchgear developed by GOHO. It complies with GB 3906, DL/T 404, and IEC 62271-200 standards, incorporating modern manufacturing techniques and materials for improved performance and reliability over earlier generation equipment.
Featuring a fixed-mounting configuration with a compact box-type enclosure, the XGN66-12 integrates vacuum circuit breakers, disconnecting switches, earthing switches, current and voltage transformers, and protective control devices into a single metal-enclosed frame. Its small footprint — with panel widths starting at just 800mm — and straightforward construction make it particularly suitable for space-constrained urban substations, indoor distribution rooms, and prefabricated substation integration where withdrawable functionality is not required.
Reliable mechanical interlocks between the circuit breaker, disconnecting switch, earthing switch, and panel door ensure correct operating sequences and prevent unsafe operations. Front-access cable termination and simple panel-to-panel busbar connections simplify installation and reduce commissioning time.
- Voltage range: 3.6kV / 7.2kV / 12kV — all standard MV levels
- Current range: 630A to 3150A — covers most distribution needs
- Short-circuit ratings: 20kA / 25kA / 31.5kA (4s)
- ZN series vacuum circuit breaker — spring operating mechanism
- Integrated disconnector + earthing switch with mechanical interlock
- Compact box-type enclosure — 800mm / 1000mm standard widths
- Lower height than conventional fixed switchgear
- Microprocessor-based protection relays with comprehensive schemes
- Front-access cable termination — easy installation
- Ideal for prefabricated substation integration

XGN66-12 Switchgear Specifications
Complete technical parameters for the 12kV fixed box-type metal-clad switchgear.
| Rated Voltage | 3.6kV / 7.2kV / 12kV |
|---|---|
| Rated Insulation Voltage | 12kV |
| Rated Frequency | 50Hz / 60Hz |
| Rated Current (Main Busbar) | 630A – 3150A |
| Rated Short-Time Withstand (Icw) | 20kA / 25kA / 31.5kA (4 seconds) |
| Rated Peak Withstand (Ipk) | 50kA / 63kA / 80kA |
| Installation Type | Fixed mounting, indoor |
| Circuit Breaker Type | Vacuum circuit breaker (ZN series) |
| Operating Mechanism | Spring-operated mechanism — manual or motor-charged |
| Disconnector | Integrated high-voltage disconnector with earthing switch |
| Instrument Transformers | Current transformers (CT) & voltage transformers (VT) — cast resin |
| Protection Relays | Microprocessor-based — overcurrent, short-circuit, earth fault, under/over voltage |
| Mechanical Endurance | ≥ 10,000 operations |
| Panel Width | 800mm / 1000mm (standard schemes) |
| Enclosure Type | Compact box-type metal enclosure |
| Degree of Protection | IP3X / IP4X (enclosure) |
| Interlocking System | Mechanical interlock between breaker, disconnector, earthing switch & door |
| Cable Termination | Front-access — single or three-core cable compatible |
| Enclosure Material | Steel plate with electrostatic spray-powder coating |
| Busbar Configuration | Single bus (standard) — single bus with bypass (optional) |
| Standard Schemes | Incoming, outgoing, metering, PT, transformer feeder, etc. |
| Applicable Standards | IEC 62271-200, GB 3906, DL/T 404 |
Compact, Reliable, and Cost-Effective
New-generation design delivers the performance of larger switchgear in a smaller, more affordable package.
Compact Box-Type Enclosure
Smaller footprint and lower height than conventional fixed switchgear — ideal for space-constrained urban substations and indoor distribution rooms.
Vacuum Circuit Breaker
ZN series VCB with sealed vacuum interrupters — low maintenance, long electrical life, and environmentally friendly operation with no SF6 gas or oil.
Reliable Mechanical Interlocking
Interlocks between breaker, disconnector, earthing switch, and panel door ensure correct operating sequences and prevent unsafe operations.
Comprehensive Protection
Supports overcurrent, short-circuit, earth fault, undervoltage, and overvoltage protection via integrated microprocessor-based relays.
New-Generation Design
Developed to latest GB 3906 and DL/T 404 standards with modern materials and manufacturing techniques — improved reliability over older designs.
Easy Installation
Simple panel-to-panel busbar connections and front-access cable termination simplify installation and reduce commissioning time.
Cost-Effective Solution
Lower initial cost than withdrawable alternatives with reduced lifetime maintenance — ideal for standard distribution projects.
Prefab Substation Ready
Compact dimensions and front-only access make it perfect for integration into compact prefabricated substations and kiosks.
Where XGN66-12 Excels
The compact workhorse for 12kV secondary distribution and space-constrained installations.
Urban & Rural Substations
Compact power distribution substations
Industrial & Mining
Power receiving & distribution
Commercial Buildings
MV switchboards for large buildings
Infrastructure
Schools, hospitals, public facilities
Secondary Distribution
10kV/12kV secondary networks
Substation Renovation
Renovation & expansion projects
Prefab Substations
Integrated into compact prefabricated units
Certified to International & National Standards
Manufactured and tested in compliance with global and Chinese national standards for medium-voltage switchgear.
Frequently Asked Questions
Common questions about XGN66-12 compact fixed switchgear. Need a custom scheme? Our engineers can help.
Both are fixed-type 12kV metal-enclosed switchgear, but they differ in design era and physical characteristics. XGN2-12 is an older, more traditional design with a larger, taller cabinet and heavier construction — it's been around for decades and is well-known in the industry. XGN66-12 is a newer, more compact design developed to modern standards. Key differences: XGN66 has a smaller footprint (800mm vs 1100mm typical width), lower overall height, uses a box-type enclosure with integrated disconnector/earthing switch, incorporates modern materials and manufacturing techniques, and is generally more cost-effective. XGN2-12 may be preferred for very high current ratings (up to 3150-4000A) or where customers have existing installations of the same type. XGN66-12 is ideal for new projects where space is at a premium and you want the latest design. Both meet IEC and GB standards.
Choose fixed-type switchgear (XGN66-12 or XGN2-12) when: you have a limited budget and want the most cost-effective solution; the application is standard distribution where breaker replacement frequency is low; floor space is limited and you want the smallest possible footprint; or you're integrating into a prefabricated substation or kiosk. Choose withdrawable switchgear (KYN28-12 or KYN61-40.5) when: maximum uptime is critical and you need the ability to swap a faulty breaker in minutes with a spare truck; you have critical loads that can't afford extended downtime; you want arc-resistant metal-clad construction for maximum operator safety; or you have a larger substation with many feeders where standardizing on one breaker type simplifies spares. As a general rule, for secondary distribution and building services, fixed-type is usually sufficient and most economical. For primary substations and critical industrial applications, withdrawable metal-clad is the premium choice.
Yes, absolutely — XGN66-12 is an excellent choice for prefabricated substations. Its compact dimensions (800mm width, lower overall height) make it ideal for integration into compact kiosk-type or pad-mounted prefabricated substations where space is at a premium. The front-access design means all connections and maintenance can be done from the front, which is perfect for enclosed prefab substation designs where you don't have rear access. It pairs well with both LV switchgear (GGD or GCS) and distribution transformers in a single enclosure. We offer complete prefabricated substation solutions with XGN66-12 as the MV section — fully assembled, wired, and factory-tested before shipment for fast on-site installation. Contact us to discuss your prefab substation requirements.
The XGN66-12 accommodates a range of protection options depending on your requirements. Standard configurations include: overcurrent protection (50/51) with earth fault (50N/51N) for basic feeder protection; undervoltage (27) and overvoltage (59) protection; and microprocessor-based multifunction relays with metering and communication capabilities. For more demanding applications, we can configure dedicated transformer protection, motor protection, or capacitor bank protection relays. The relay panel includes meters, indicator lamps, control switches, and selector switches as needed. Communication options include Modbus RTU/TCP for SCADA integration. Provide us with your protection philosophy or single-line diagram and we'll design a complete protection and control package fully tested at our factory.
Fixed-type switchgear has relatively low maintenance requirements. A typical maintenance schedule includes: annual visual inspection of the cabinet interior, busbar connections, and insulation condition; cleaning of internal compartments every 2-3 years (requires de-energizing); mechanical operation check of disconnector and earthing switch (annually); spring mechanism lubrication and inspection every 3-5 years; vacuum breaker contact wear monitoring based on operation count; and relay calibration and testing every 2-5 years per utility or plant standards. The main difference from withdrawable switchgear is that for breaker maintenance in a fixed-type panel, the panel needs to be de-energized and isolated — you can't simply roll out the breaker. For this reason, it's best suited to applications where planned maintenance outages are acceptable. We provide detailed maintenance manuals with every shipment and can also offer service contracts and on-site support.
The standard XGN66-12 is designed for indoor installation with IP3X or IP4X protection. It's intended for use inside a substation building, equipment room, or electrical switchroom where it's protected from direct weather exposure. For outdoor applications, we offer two options: install the XGN66-12 inside a weatherproof enclosure or prefabricated substation (our YBM or ZBW series), which provides the necessary weather protection and is a common solution for outdoor compact substations; or use our outdoor-rated switchgear products like the HXGN15-12 RMU or DFW-12 cable branch box, which are specifically designed for direct outdoor installation with higher IP ratings (IP67). If you need outdoor MV switchgear, let us know your application details and we'll recommend the best solution from our product range.
Complete MV & LV Switchgear Range
From compact fixed-type to premium withdrawable — one supplier for your entire switchgear lineup.
Configure Your Compact Switchgear
Send us your single-line diagram and protection requirements. Get a compact XGN66-12 switchgear with the right schemes and relays — perfect for space-constrained installations.
Get a Project Quote