DBX-3000 Single-Phase Electricity Meter Box | 220V, IP30/IP40, Tamper-Proof | GOHO
GOHO DBX-3000 single-phase electricity meter box
Electricity Meter Box

DBX-3000 Single-Phase Electricity Meter Box

DBX-3000 type electric meter box is a terminal distribution enclosure for installing single-phase electric energy meters (220V), used for revenue metering and power distribution in residential apartments, dormitories, villas, retail shops, and small offices. It provides a standardized, secure, and tamper-proof housing for utility-grade metering equipment with a clear utility-consumer physical partition — the utility side (incoming cable, meter, seals) remains sealed, while the consumer side (outgoing MCB) is accessible for occupant resets.

220V / 230V / 240V Up to 100A Tamper-Proof Sealed Transparent Window
240V
Max Rated Voltage
100A
Max Main Current
1
Meter Per Unit
IP40
Max Protection

Secure Single-Phase Revenue Metering with Utility-Consumer Split

Tamper-proof metering compartment + separate consumer MCB access for billing compliance

DBX-3000 type electric meter box is a terminal distribution enclosure designed for installing single-phase electric energy meters (220V), primarily used for revenue metering and power distribution in civil buildings (residential apartments, dormitories, villas) and commercial outlets (retail shops, small offices, storefronts). It provides a standardized, secure, and tamper-proof housing for utility-grade electricity metering equipment in compliance with applicable metering regulations.

The enclosure accommodates one single-phase meter per unit compartment, with dedicated, physically separated spaces for the incoming utility service cable, the metering device, and the outgoing consumer-side overcurrent protection device. This clear utility-consumer demarcation meets the isolation requirements of electricity supply regulations, ensuring that utility-owned metering equipment remains sealed and inaccessible to the consumer while allowing the consumer convenient access to their own protective device.

With a transparent polycarbonate reading window for non-intrusive meter reading, a sealable utility compartment, and a separate consumer door for MCB access and reset, the DBX-3000 delivers a complete single-phase metering solution for apartment buildings, houses, retail shops, small offices, dormitories, and utility domestic service connections. Available in cold-rolled steel powder-coated or ABS plastic, IP30/IP40, with surface or flush wall mounting.

  • 220V/230V/240V — single-phase, 1 meter per unit
  • Up to 100A — utility MCCB / isolator incoming
  • Utility-consumer partition — sealed meter compartment
  • Transparent window — non-intrusive meter reading
  • Consumer MCB — separate accessible compartment
  • IP30/IP40 indoor — surface or flush wall mount
DBX-3000 single-phase meter box with transparent reading window

Detailed Parameters

Complete technical specifications for DBX-3000 single-phase electricity meter box

ParameterSpecification
Rated Voltage220V / 230V / 240V AC (single-phase)
Rated Frequency50Hz / 60Hz
Rated Current (Main Busbar)Up to 100A
Meter ConfigurationSingle-phase, 1 meter per unit
Meter Type CompatibilityDIN-rail mounted (standard) or base-mounted electronic/mechanical meter
Incoming ProtectionUtility-side MCCB or double-pole isolator (up to 100A)
Outgoing ProtectionConsumer-side MCB (up to 63A, 1P or 1P+N)
Metering CompartmentSealable with utility-standard lock or padlock hasp
Consumer CompartmentAccessible via separate door or cover
Degree of ProtectionIP30 / IP40 (indoor)
Installation TypeIndoor, wall-mounted (surface or flush)
Enclosure MaterialCold-rolled steel with anti-corrosion powder coating or engineering ABS plastic
Meter Reading WindowHigh-impact transparent polycarbonate
Busbar MaterialTin-plated copper (incoming & outgoing)
Insulation Voltage (Ui)400V
Pollution Degree2
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to +70°C
Ambient Humidity≤ 95% (non-condensing)
Altitude≤ 2000m
Cable EntryTop/bottom knock-out openings with glands
ColorLight grey / white (customizable)
SealingWire-and-seal or padlock hasp (utility side)
StandardsGB/T 7251, IEC 61439

Why Choose DBX-3000 Meter Box

Purpose-built, tamper-proof single-phase metering with utility-consumer separation

Purpose-Built Metering Enclosure

Designed specifically for single-phase 220V electricity metering applications in residential and light commercial environments — standardized internal dimensions and mounting points ensure compatibility with standard form-factor utility meters and common installation practices used by electricity distribution companies, avoiding the need for custom modifications.

Clear Utility-Consumer Demarcation

Internal physical partition clearly separates the utility-controlled metering compartment (incoming cable, meter terminals, utility seals) from the consumer-accessible distribution compartment (outgoing MCB, load cables), ensuring full compliance with electricity supply regulations requiring physical separation between utility and consumer equipment to prevent meter tampering and unauthorized supply connection.

Tamper-Evident Sealing

The metering compartment door or cover is designed to accommodate utility-standard wire-and-seal or padlock sealing mechanisms — any attempt to access the meter terminals or incoming supply connections results in visible seal breakage, providing a clear tamper-evident indication during periodic meter reading or inspection by utility field staff.

Transparent Meter Reading Window

A high-impact transparent polycarbonate window is provided in the metering compartment door, allowing utility field staff to read the meter display or perform optical meter interrogation without opening the enclosure — maintaining seal integrity and reducing the risk of accidental seal breakage during routine reading operations.

Integrated Overcurrent Protection

A dedicated consumer-side MCB (miniature circuit breaker) is housed in the separately accessible consumer compartment, providing short-circuit and overload protection for the downstream consumer installation while remaining easily resettable by the occupant or facility manager after a fault event — no utility intervention required for routine MCB reset.

Surface or Flush Mounting

The compact enclosure design supports both surface-mounted (direct wall fixing with exposed conduit) and flush-mounted (recessed into wall cavity) installation methods, providing flexibility for different building construction types and interior design requirements — from modern apartments with wall cavities to older buildings requiring surface conduit.

Durable Indoor Construction

Corrosion-resistant cold-rolled steel with electrostatic powder coating or UV-stabilized ABS plastic provides reliable long-term service in indoor environments including residential stairwells, corridors, utility rooms, and meter cupboards — resistant to impact, humidity, and normal building contaminants over many years of service.

Standard Meter Compatibility

Accommodates both DIN-rail mounted (standard) and base-mounted electronic or mechanical single-phase meters, ensuring compatibility with the meter models specified or supplied by the local utility company — no need to source a special meter form factor to fit the enclosure.

Compliant Metering Isolation

The physical separation between utility and consumer compartments, combined with sealable utility access and transparent reading, ensures the DBX-3000 meets the isolation and anti-tamper requirements of most electricity supply regulations — suitable for utility-owned revenue metering points and multi-tenant buildings where per-occupant billing is required.

Where DBX-3000 Meter Box Excels

Single-phase revenue metering for residential and light commercial premises

Apartment Buildings

Per-apartment revenue metering

Houses & Villas

Household electricity metering

Retail Shops

Tenant metering & billing

Small Offices

Individual consumer metering

Dormitories

Per-occupant electricity billing

Utility Connections

Single-phase domestic service points

Mixed-Use Buildings

Multi-tenant sub-metering

Meter Cupboards

Centralized metering banks

Quality & Compliance

Certified for safe and tamper-proof single-phase revenue metering

IEC 61439

Low-voltage switchgear assemblies

GB/T 7251

LV complete switchgear standard

Tamper-Evident

Sealed utility compartment

ISO 9001

Quality management certified

Frequently Asked Questions

Common questions about DBX-3000 single-phase electricity meter boxes

What is the difference between DBX-3000 and GHBX meter boxes?

Both the DBX-3000 and GHBX are single-phase electricity meter boxes, but they are designed for slightly different applications and feature sets: (1) DBX-3000 — emphasizes a clear utility-consumer physical partition with separate compartments and doors. The utility side (meter, incoming cable) is sealable and inaccessible to the consumer; the consumer side (outgoing MCB) has its own separate door for occupant access and reset. It includes an integrated consumer-side MCB as standard. (2) GHBX — focuses on a transparent polycarbonate reading window and anti-tamper design, with dedicated phase, neutral, and earth conductor connection points. Both accept DIN-rail or base-mounted meters and serve the same residential/commercial single-phase metering market. The DBX-3000 is the better choice where strict utility-consumer separation and independent consumer MCB access are required by local regulations; the GHBX is preferred where a clean, transparent-window aesthetic and simplified wiring are priorities. Both are compliant with IEC 61439 and GB/T 7251.

Why is the utility-consumer partition important for metering?

The utility-consumer physical partition is a regulatory requirement in most electricity supply jurisdictions for revenue-metering installations. Its purpose is to: (1) Prevent meter tampering — the consumer cannot access the meter terminals, current transformer (CT) connections, or the incoming supply cable, eliminating the possibility of bypassing the meter or altering its readings. (2) Define ownership and responsibility — the utility owns and maintains everything upstream of and including the meter; the consumer owns and is responsible for everything downstream (outgoing MCB and internal wiring). (3) Enable sealing — the utility compartment can be sealed with a wire seal or padlock, so any unauthorized access is immediately visible as a broken seal. (4) Allow consumer reset of the MCB — the consumer can reset a tripped outgoing MCB without needing utility access or breaking the meter seal. Without this partition, the consumer could potentially tamper with the meter, leading to revenue loss for the utility and safety hazards from improper modifications.

Can the DBX-3000 accommodate a smart/electronic meter?

Yes. The DBX-3000 is compatible with both electronic (smart) and mechanical single-phase meters, supporting either DIN-rail mounting (the most common for modern electronic meters) or base mounting (for traditional meters with screw terminals). For smart meters that require communication wiring (e.g., for RF, PLC, or cellular communication modules), ensure adequate space is reserved inside the metering compartment for the communication antenna or module — this is usually not an issue with standard form-factor meters. When specifying, indicate the meter brand and model so we can confirm the mounting type (DIN-rail vs. base) and dimensions. Note that for smart meters with remote disconnect relays, the incoming supply switching is performed by the meter itself, so the separate utility-side isolator or MCCB may be optional — confirm with the utility's metering specification.

How is the meter box sealed, and who holds the keys?

The utility metering compartment is sealed using either a utility-standard wire-and-seal (lead seal or plastic security seal) or a padlock hasp. The sealing method depends on the utility company's standard practice: (1) Wire-and-seal — a plastic or lead security seal is threaded through the sealing eyelets on the compartment door and crimped. The seal is numbered or barcoded for traceability. This is the most common method and is tamper-evident (the seal must be broken to open the door). (2) Padlock hasp — a small padlock is fitted through the hasp. The utility holds the only key. This is used in some regions for higher-security installations. In both cases, only the utility company has the ability to open the metering compartment legally. The consumer compartment (MCB) has a separate, non-sealed door that the consumer can open freely to reset a tripped breaker. The seal must be inspected and replaced by the utility whenever the compartment is opened for meter reading, testing, or maintenance.

Can the DBX-3000 be used for three-phase metering?

No. The DBX-3000 is specifically designed for single-phase (220V/230V/240V) metering only. It accommodates one single-phase meter per unit and is rated for up to 100A main current. For three-phase (380V/400V) metering applications — such as for residential units with three-phase supply, small commercial premises with three-phase loads, or industrial customers — a three-phase meter box is required. GOHO's JP series outdoor distribution box includes three-phase metering configurations, and for indoor three-phase metering we can supply a custom three-phase meter box based on the XL-21 or GHM platform with a meter compartment. When requesting a three-phase metering solution, specify the voltage (380V/400V), current rating, whether CT (current transformer) metering is required for high currents, and the utility-consumer separation requirements. Do not attempt to use the single-phase DBX-3000 for three-phase service, as this would create a serious safety and regulatory non-compliance issue.

What incoming and outgoing devices should I specify?

The device selection depends on the utility's requirements and the consumer's load: (1) Incoming (utility-side) device — typically a double-pole isolator or a double-pole MCCB rated up to 100A. The isolator provides a visible break point for safe isolation; the MCCB adds overload and short-circuit protection on the supply side. The utility usually specifies which type is required. If the incoming supply is protected by an upstream device (e.g., the building's main distribution board), an isolator may be sufficient. (2) Outgoing (consumer-side) device — a single-pole (1P) or 1P+N MCB rated up to 63A, with a trip curve (B, C, or D) selected based on the load type. For typical residential installations, a 32A–63A Type C MCB is common. The MCB rating should be matched to the consumer's main cable size and the total connected load. We can supply the DBX-3000 empty (for on-site device installation) or fully pre-wired with the specified incoming and outgoing devices. Always confirm device requirements with the local utility company before ordering, as metering installation standards vary by region.

Secure Single-Phase Revenue Metering

Tell us your meter type (DIN-rail or base), incoming device (isolator or MCCB), consumer MCB rating, and mounting preference. We'll configure the DBX-3000 with the correct utility-consumer partition and sealing arrangement with a factory quote in 24 hours.