GG-1A switchgear

GG-1A Switchgear | 3kV-10kV Fixed Indoor AC Metal-Enclosed Switchgear | GOHO
GOHO GG-1A(F) fixed indoor AC metal-enclosed switchgear lineup
Fixed MV Switchgear

GG-1A(F) Fixed Indoor AC Metal-Enclosed Switchgear

GG-1A(F) series fixed-type medium voltage switchgear — 3kV to 10kV, 630A to 4000A, for three-phase AC single busbar and single busbar with bypass systems. The industry-proven workhorse of MV distribution with decades of reliable field service. Arc-resistant F-type variant with reinforced pressure relief for enhanced operator safety.

3kV – 10kV Fixed Mounting Arc-Resistant F-Type Up to 4000A
3–10kV
Rated Voltage
4000A
Max Current
31.5kA
Short-Time (4s)
IP2X–IP3X
Protection

Industry-Proven Fixed MV Switchgear

Decades of reliable service in power distribution networks across industrial, utility, and infrastructure sectors

The GG-1A(F) fixed indoor AC metal-enclosed switchgear is a proven solution for receiving and distributing electric energy in three-phase AC single busbar and single busbar bypass systems with rated voltage of 3kV to 10kV and rated frequency of 50Hz/60Hz. It is one of the most widely deployed fixed-type medium voltage switchgear models in China's power distribution networks, with a track record spanning several decades of reliable operation across industrial plants, substations, and utility networks.

The "F" designation indicates the arc-resistant variant, which incorporates reinforced arc containment and pressure-relief features to enhance operator safety during internal arc fault events. The switchgear adopts a fixed-mounting open-frame construction with all main components — including circuit breakers, disconnectors, current and voltage transformers, and protective relays — permanently mounted on a steel frame structure within a metal-enclosed housing. This open-frame design provides excellent ventilation, easy access for inspection, and straightforward maintenance with complete visibility of all components.

  • 3kV–10kV voltage range — covers all standard medium-voltage distribution levels
  • 630A–4000A current range — standard up to 3150A, customizable to 4000A
  • Arc-resistant F-type variant — pressure-relief design for enhanced operator safety
  • Fixed open-frame construction — excellent ventilation, easy inspection and maintenance
  • Single busbar with bypass — continued power supply during feeder maintenance
  • Vacuum or SF6 breaker options — ZN series VCB or SF6 circuit breaker compatibility
GG-1A(F) fixed metal-enclosed switchgear front view

Detailed Parameters

Complete technical specifications for GG-1A(F) series fixed indoor switchgear

ParameterSpecification
Rated Voltage3kV / 6kV / 10kV
Rated Insulation Voltage12kV
Rated Frequency50Hz / 60Hz
Rated Current (Main Busbar)630A – 3150A (standard) / up to 4000A (custom)
Rated Short-Time Withstand Current (Icw)20kA / 25kA / 31.5kA (4s)
Rated Peak Withstand Current (Ipk)50kA / 63kA / 80kA
Busbar SystemSingle busbar / Single busbar with bypass
Degree of ProtectionIP2X – IP3X (enclosure)
Installation TypeFixed mounting, indoor
Circuit Breaker TypeVacuum circuit breaker (ZN series) or SF6 (optional)
Switching Device OptionsCircuit breaker / Load switch / Disconnector / Earthing switch combinations
Operation MechanismManual spring-operated or electromagnetic mechanism
Mechanical Endurance≥ 2,000 operations (disconnector)
Arc Resistance (F-Type)Internal arc fault containment with pressure relief
Cable Termination SpaceGenerous cable compartment for easy termination
Ambient Temperature-5°C to +40°C (indoor)
Ambient Humidity≤ 90% (non-condensing)
Altitude≤ 1000m (derated above)
StandardsGB 3906, DL/T 404, IEC 62271-200

Why Choose GG-1A(F) Switchgear

Proven reliability, flexible configuration, and cost-effective medium voltage distribution

Fixed Open-Frame Construction

All components are permanently mounted on a steel frame within the enclosure. The open-frame design provides excellent ventilation, easy access for inspection, and straightforward maintenance with complete visibility of all components.

Arc-Resistant F-Type Variant

The reinforced arc-resistant design incorporates pressure-relief flaps and strengthened door latches to safely contain and vent arc fault gases, protecting operating personnel in accordance with IEC 62271-200.

Industry-Proven Platform

GG-1A(F) is one of the most widely adopted fixed switchgear models in Chinese power distribution history, with thousands of installations operating reliably across industrial plants, substations, and utility networks for decades.

Flexible Busbar Configuration

Supports single busbar and single busbar with bypass systems. The bypass configuration enables continued power supply to critical loads during maintenance of individual feeder circuits, maximizing system availability.

Versatile Component Compatibility

Compatible with a wide range of switching devices — vacuum circuit breakers (ZN series), load switches, disconnectors, and earthing switches — allowing customization to specific application requirements and budget constraints.

Cost-Effective Solution

Lower initial investment and simpler maintenance requirements compared to withdrawable alternatives of equivalent rating, making it the preferred choice for standard medium voltage distribution projects with limited budgets.

Large Cable Termination Space

The generous enclosure dimensions provide ample space for cable entry, termination, and CT/VT installation, simplifying on-site cable connection and reducing installation time and labor costs.

Type-Tested & Certified

The F-type variant design has been verified through extensive type testing to withstand and contain internal arc faults, providing certified operator protection. Full compliance with GB 3906, DL/T 404, and IEC 62271-200 standards.

Simple Operation & Maintenance

Manual spring-operated or electromagnetic mechanisms with clear visual indicators. Open-frame design allows complete component visibility for quick inspection and straightforward maintenance procedures.

Where GG-1A(F) Excels

Versatile fixed-type switchgear for diverse medium voltage distribution applications

Industrial Substations

Power receiving & distribution for factories and plants

Power Plants

Thermal & hydro plant auxiliary power systems

Mining & Metallurgy

Mining operations and metallurgy power supply

Commercial Buildings

MV distribution for commercial & institutional buildings

Utility Distribution

Urban and rural distribution substations

Substation Renovation

Existing substation renovation & capacity expansion

Industrial Main Switchboards

Small to medium industrial facility main switchboards

Infrastructure Projects

Water treatment plants, data centers, infrastructure

Quality & Compliance

Type-tested and certified for reliable medium voltage distribution performance

IEC 62271-200

AC metal-enclosed switchgear standard

CCC / CQC

China Compulsory Certification

ISO 9001

Quality management system

Type Tested

Full electrical & arc fault type testing

Frequently Asked Questions

Common questions about GG-1A(F) fixed metal-enclosed switchgear

What's the difference between GG-1A and GG-1A(F) switchgear?

The "F" designation in GG-1A(F) stands for "arc-resistant" (fang hu in Chinese). The standard GG-1A is a basic fixed metal-enclosed switchgear, while the GG-1A(F) variant incorporates reinforced arc containment features including pressure-relief flaps on the top and rear of the enclosure, strengthened door latches and hinges, and additional structural reinforcement to safely contain and direct internal arc fault gases away from operating personnel. The F-type variant provides certified protection against internal arc faults in accordance with IEC 62271-200, making it the preferred choice for applications where operator safety is a priority. Both versions share the same basic fixed open-frame construction, electrical ratings, and component compatibility.

How does fixed-type switchgear compare to withdrawable (drawout) switchgear?

Fixed-type switchgear like GG-1A has all components permanently mounted on a steel frame, while withdrawable switchgear (like KYN28-12) features a removable circuit breaker truck that can be racked in/out. Fixed switchgear advantages include: lower initial cost (typically 30-50% less than equivalent withdrawable), simpler design with fewer moving parts, excellent ventilation from the open-frame design, and easier access for inspection. Withdrawable switchgear advantages include: faster breaker replacement (minutes vs hours), better safety isolation through racking positions, and more compact front-access-only design. Choose GG-1A for standard distribution applications where budget is important and maintenance can be scheduled during planned outages. Choose withdrawable switchgear for critical applications requiring maximum uptime and where quick breaker replacement is essential.

What is a single busbar with bypass system, and when is it needed?

A single busbar with bypass system adds a bypass busbar alongside the main busbar, along with bypass disconnectors. This allows any feeder circuit breaker to be bypassed — the load is transferred to the bypass bus through the bypass disconnector, allowing the main circuit breaker to be isolated and removed for maintenance or replacement without interrupting power to the load. This configuration is particularly useful for critical loads that cannot tolerate extended downtime, such as continuous process industries, hospitals, data centers, and essential infrastructure. The GG-1A(F) supports both standard single busbar and single busbar with bypass configurations, giving you flexibility to match your specific availability requirements. The bypass feature adds some cost and complexity but significantly improves system maintainability.

What circuit breaker options are available for GG-1A switchgear?

The GG-1A switchgear is compatible with a range of switching devices to suit different application requirements and budgets. The primary options are: vacuum circuit breakers (ZN series) — the most common choice, offering long electrical life, low maintenance, and excellent interruption performance; SF6 circuit breakers — available as an option for applications preferring SF6 technology; load break switches — for lower-rated circuits requiring load switching without full fault protection; and disconnector/earthing switch combinations — for isolation and grounding purposes in distribution circuits. The flexible design also accommodates different operating mechanisms including manual spring-operated and electromagnetic mechanisms. Tell us your application requirements and we'll recommend the optimal switching device configuration for your project.

Can GG-1A switchgear be used for outdoor installations?

No, the GG-1A series is designed for indoor installation only with IP2X to IP3X degree of protection. It is not weatherproof and cannot be directly exposed to rain, snow, or extreme temperature variations. For outdoor applications, we recommend our prefabricated compact substation solutions (YBM, ZBW, etc.) which house medium voltage switchgear inside a weatherproof enclosure with proper ventilation, heating, and protection. Alternatively, the GG-1A can be installed inside an outdoor equipment shelter or substation building that provides environmental protection. If you need outdoor-rated MV switchgear, please contact us to discuss our outdoor switchgear options or prefabricated substation solutions that are specifically designed for outdoor installation.

What is the lead time for GG-1A switchgear and can it be customized?

Standard GG-1A switchgear typically has a lead time of 4-6 weeks for standard configurations, depending on the quantity and specific requirements. The GG-1A is highly customizable to meet specific project needs. Customization options include: current ratings up to 4000A, various short-circuit ratings (20kA, 25kA, 31.5kA), choice of circuit breaker type and manufacturer, busbar configuration (single or with bypass), protection relay selection (electromechanical or digital/microprocessor-based), metering and instrumentation options, cable termination arrangements, painting/color options, and special features for specific industries. For custom configurations, lead time may be slightly longer. We recommend contacting us early in your project planning so we can provide accurate delivery estimates and ensure the configuration meets all your technical requirements.

Need Fixed-Type MV Switchgear?

Send us your project specifications — voltage, current, short-circuit rating, and configuration. We'll configure the right GG-1A(F) switchgear solution, including arc-resistant F-type and bypass options.

Scroll to Top