PGX-2000 Ribbed Distribution Box
PGX-2000 rib box is suitable for various building applications with rated current up to 225A and multiple circuits, used for lighting and power distribution in commercial, residential, and light industrial environments. The internal component mounting plate adopts an adjustable track system with movable mounting blocks, enabling true modular installation and flexible configuration of DIN-rail devices including MCBs, RCCBs, RCBOs, contactors, and terminal blocks. The human-centric ribbed panel design with clean lines and concealed fixings delivers a refined finish suitable for exposed installation in aesthetically sensitive environments.
Modular Distribution Box with Adjustable Track & Ribbed Aesthetic
4–24 circuits, reconfigurable DIN-rail layout, and a clean ribbed door for exposed installation
PGX-2000 rib box is suitable for various building applications with rated current up to 225A and multiple circuits, used for lighting and power distribution in commercial, residential, and light industrial environments. The internal component mounting plate adopts an adjustable track system with movable mounting blocks, enabling true modular installation and flexible configuration of DIN-rail mounted devices including MCBs, RCCBs, RCBOs, contactors, and terminal blocks.
Standardization of component layouts and the use of new manufacturing technologies fully meet the requirements of project sites for device form factor, dimensions, and installation compatibility. The adjustable track approach — shared with GOHO's QHX dual power box and DBX-5000 meter box — means devices can be added, removed, or repositioned by sliding the movable blocks along the track, with no drilling or plate modification required.
The human-centric appearance design with clean ribbed panel lines conveys simplicity and extremely high build quality, making the PGX-2000 suitable for exposed installation in aesthetically sensitive environments such as office buildings, retail spaces, hotels, and public facilities. Cold-rolled steel construction with electrostatic epoxy powder coating ensures mechanical protection, impact resistance, and long-term corrosion protection for reliable indoor service.
- 400V / 415V — up to 225A main busbar
- 4–24 outgoing circuits — configurable
- Adjustable track + movable blocks — no drilling
- DIN-rail devices — MCB, RCCB, RCBO, contactor, terminals
- Ribbed steel door — aesthetic exposed installation
- Cold-rolled steel + epoxy — IP40 indoor wall mount

Detailed Parameters
Complete technical specifications for PGX-2000 ribbed distribution box
| Parameter | Specification |
|---|---|
| Rated Voltage | AC 400V / 415V |
| Rated Frequency | 50Hz / 60Hz |
| Rated Current (Main Busbar) | Up to 225A |
| Number of Outgoing Circuits | 4 – 24 circuits (configurable) |
| System Configuration | Three-phase / single-phase |
| Enclosure Material | Cold-rolled steel with epoxy powder coating |
| Degree of Protection | IP40 (indoor) |
| Mounting System | Adjustable track with movable blocks |
| Device Compatibility | Standard DIN-rail 9mm/18mm modular devices |
| Supported Devices | MCB, RCCB, RCBO, contactor, terminal blocks |
| Installation Type | Indoor, wall-mounted (surface) |
| Cable Entry | Top and bottom knock-out openings |
| Door Type | Steel door with ribbed panel design |
| Busbar Material | Tin-plated copper |
| Insulation Voltage (Ui) | 690V |
| Impulse Withstand Voltage (Uimp) | 6kV |
| Pollution Degree | 2 / 3 |
| Operating Temperature | -25°C to +40°C |
| Storage Temperature | -40°C to +70°C |
| Ambient Humidity | ≤ 95% (non-condensing) |
| Altitude | ≤ 2000m |
| Color | Light grey / white (customizable) |
| Fixings | Concealed (aesthetic finish) |
| Standards | GB/T 7251, IEC 61439 |
Why Choose PGX-2000 Distribution Box
Modular reconfigurable layout, robust steel build, and a refined ribbed aesthetic
Flexible Modular Mounting System
Adjustable track with movable mounting blocks enables quick repositioning, addition, or replacement of DIN-rail mounted devices without drilling or plate modification — supporting modular circuit configurations up to 24 outgoing ways with maximum layout flexibility for different project requirements.
Human-Centric Aesthetic Design
Clean ribbed panel appearance with smooth lines and concealed fixings delivers a refined, professional finish suitable for exposed installation in visually sensitive environments including office buildings, retail spaces, hotels, and public facilities where equipment appearance matters as much as function.
Standardized Construction
Factory-standardized internal layouts, busbar configurations, and wiring schemes ensure consistent build quality and simplify future modifications — standardized mounting centres and knockout positions are compatible with common project specifications and installation practices, reducing on-site errors and rework.
Robust Steel Construction
Cold-rolled steel enclosure with electrostatic epoxy powder coating provides excellent mechanical protection, impact resistance, and long-term corrosion protection for reliable indoor service in commercial, residential, and light industrial environments, withstanding normal handling and site conditions.
Broad Device Compatibility
Accepts standard 9mm/18mm modular DIN-rail devices from any manufacturer — MCBs for overcurrent, RCCBs and RCBOs for residual-current protection, contactors for motor or load control, and terminal blocks for wiring distribution — giving installers freedom of component choice and easy replacement.
Configurable Circuit Count
Available with 4 to 24 outgoing circuits, configurable to match the specific load schedule of each project — from small residential floor distribution (4–8 ways) to larger commercial floor panels (12–24 ways) — with the adjustable track allowing circuits to be added or reorganized as the load evolves.
Top & Bottom Cable Entry
Knock-out openings on both the top and bottom of the enclosure accommodate incoming supply cables and outgoing load cables in logical top-to-bottom or bottom-to-top routing arrangements, supporting both overhead and underground cable configurations on the same enclosure.
Ribbed Door with Concealed Fixings
The steel door features a ribbed panel that adds rigidity and a clean architectural aesthetic, while all mounting fixings are concealed behind the door or trim — eliminating visible screw heads for a premium appearance when the box is surface-mounted in occupied or public spaces.
High Current Capacity
With a main busbar rated up to 225A and a 400V/415V system voltage, the PGX-2000 covers both single-phase and three-phase small-power distribution — suitable for floor-level distribution in commercial buildings, multi-circuit lighting panels, and small machine power distribution in light industry.
Where PGX-2000 Distribution Box Excels
Multi-circuit lighting and power distribution across building types
Commercial Buildings
Lighting & small power distribution
Residential
Apartment floor distribution
Office Buildings
Floor-level lighting & power
Retail & Hotels
Shop & restaurant power
Light Industry
Small machine power & lighting
Public Facilities
Exposed aesthetic installation
Floor Distribution
Multi-floor building panels
Retrofit Projects
Reconfigurable circuit upgrades
Quality & Compliance
Certified for indoor multi-circuit power distribution
IEC 61439
Low-voltage switchgear assemblies
GB/T 7251
LV complete switchgear standard
IP40 Rated
Indoor protection against objects
ISO 9001
Quality management certified
Frequently Asked Questions
Common questions about PGX-2000 ribbed distribution boxes
Both are indoor low-voltage distribution boxes for lighting and small-power circuits, but they differ in construction, capacity, and aesthetics: (1) Mounting system — PGX-2000 uses an adjustable track with movable mounting blocks, allowing DIN-rail devices (MCB, RCCB, RCBO, contactor, terminal blocks) to be repositioned, added, or replaced without drilling or plate modification; GHM uses a conventional fixed DIN-rail mounting plate. (2) Capacity — PGX-2000 supports up to 225A main busbar and 4–24 outgoing circuits, covering larger floor-distribution panels; GHM is typically rated for lower currents and fewer ways as a final distribution box. (3) Aesthetics — PGX-2000 has a ribbed steel door with concealed fixings for a premium, exposed-installation appearance; GHM has a standard plain door. (4) Installation — PGX-2000 is surface (wall) mounted only; GHM is available in both surface and flush configurations. Choose PGX-2000 for projects needing flexible circuit reconfiguration, higher current capacity, or a refined exposed appearance; choose GHM for standard fixed-layout final distribution where flush mounting is required.
The adjustable track mounting system (shared with GOHO's QHX dual power box and DBX-5000 meter box) works as follows: (1) Horizontal or vertical mounting rails (tracks) are fixed to the internal mounting plate. (2) Movable mounting blocks slide freely along these tracks and can be locked at any position by tightening their set screws. (3) The DIN rail (for MCBs, RCCBs, RCBOs, contactors) and terminal blocks are bolted to the movable blocks. (4) To reconfigure — add a circuit, change device width, or reorganize the layout — loosen the blocks, slide the DIN rail and components to the new position, and retighten. No drilling, no tapping, no replacement mounting plate. This is valuable for projects where the circuit count or device mix may change during construction, for retrofit installations, or for maintenance teams that need to swap components quickly. The same enclosure can serve many different circuit configurations, reducing the need to stock multiple enclosure variants.
The PGX-2000 accepts standard 9mm/18mm modular DIN-rail mounted devices from any manufacturer, including: (1) MCBs (miniature circuit breakers) — for overload and short-circuit protection of outgoing circuits, 1P, 2P, 3P, 4P. (2) RCCBs (residual current circuit breakers) — for earth-leakage protection on a group of circuits. (3) RCBOs (residual current breakers with overcurrent) — combined overcurrent + earth-leakage protection per circuit. (4) Contactors — for remote or automatic control of lighting or small motor loads. (5) Terminal blocks — for neutral/earth distribution and load wiring. (6) Isolators / main switches — for the incoming supply. Incoming protection is typically an MCCB or main switch up to 225A, and outgoing protection is MCBs/RCBOs sized per circuit. Because the DIN rail is on adjustable track blocks, the device layout can be customized to fit any combination. When specifying, provide the single-line diagram and device list so we can pre-configure the track layout and ship the box fully wired, or supply it empty for on-site assembly.
The PGX-2000 is designed for indoor, surface (wall) mounted installation only: (1) Protection rating — IP40, suitable for indoor dry environments (corridors, electrical rooms, meter cupboards, offices, retail back-of-house). It is not rated for outdoor use. (2) Mounting — surface-mounted only (fixed directly to the wall surface); it is not available as a flush/recessed version. (3) For outdoor distribution — consider the JP series outdoor comprehensive distribution box, which is purpose-built for exposed outdoor service with higher IP rating and UV resistance. (4) For flush-mounted indoor distribution — consider the GHM series, which offers both surface and flush configurations. The PGX-2000's surface-only design is intentional: the ribbed aesthetic door is meant to be seen, so it is optimized for exposed indoor installation where appearance matters. Always ensure the operating temperature range (-25°C to +40°C) and non-condensing humidity (≤95%) are respected.
The PGX-2000 supports 4 to 24 outgoing circuits, selected based on your load schedule: (1) Small residential floor or shop — 4–8 ways. (2) Larger apartment floor or small office — 8–12 ways. (3) Commercial floor or multi-zone lighting — 12–24 ways. When choosing, size for the current circuit count plus 10–20% spare ways for future circuits. (2) Adding circuits later — because the PGX-2000 uses the adjustable track system, additional MCBs/RCBOs can be added within the existing enclosure up to the configured maximum way count, simply by sliding the DIN rail blocks to create space. You do not need to drill new holes or replace the mounting plate. However, if you need more ways than the enclosure's configured maximum, you would need a larger enclosure. To maximize future flexibility, we recommend ordering the enclosure with the maximum way count you anticipate, even if some ways are initially blanked off — the adjustable track means you can populate spares later without enclosure modification.
Yes. The PGX-2000 is rated at 400V/415V AC with a main busbar up to 225A, making it suitable for both single-phase and three-phase distribution: (1) Three-phase incoming — a 3P+N or 4P main MCCB (up to 225A) feeds a three-phase busbar system (L1, L2, L3, N, PE). (2) Outgoing circuits — can be a mix of three-phase (3P or 3P+N MCB) and single-phase (1P MCB, distributed across the three phases) circuits, allowing balanced three-phase load distribution across multiple single-phase final circuits. (3) Single-phase incoming — a 2P main switch feeds a single-phase busbar, with single-phase outgoing MCBs. (4) For higher three-phase currents or larger motor loads, consider the XL-21 power cabinet or GGD/GCS switchgear instead. The PGX-2000 is best suited to small-power and lighting distribution at floor or zone level, not to main incoming or large motor control. Provide your single-line diagram so we can confirm the busbar rating, phase balance, and device configuration for your specific application.
Explore More Distribution & Switchgear Solutions
Complete range of distribution boxes and LV switchgear from GOHO

GHM Distribution Box
Surface/flush final distribution box.
Learn More
DBX-5000 Meter Box
Adjustable-track single-phase metering.
Learn More
XL-21 Power Cabinet
Floor-standing LV power distribution.
Learn More
YBM Compact Substation
Complete MV/LV prefabricated substation.
Learn MoreReconfigurable Distribution for Any Circuit Layout
Send us your single-line diagram with the number of outgoing circuits, device list (MCB/RCCB/RCBO/contactor ratings), main incoming current, and phase configuration (single- or three-phase). We'll configure the PGX-2000 with the correct adjustable-track DIN-rail layout and busbar rating — and it can be reconfigured later without enclosure modification. Factory quote in 24 hours.