S11 / S13 / S20 / S22 Series Three-Phase Oil-Immersed Fully Sealed Distribution Transformer (10kV / 20kV)

S11 Oil-Immersed Distribution Transformer | 10kV/20kV, 30–2500kVA, Fully Sealed | GOHO
GOHO S11 oil-immersed fully sealed distribution transformer
Oil-Immersed Transformer

S11 Oil-Immersed Distribution Transformer

The GOHO S11 series is a three-phase oil-immersed, fully sealed distribution transformer with a corrugated-wall tank and no oil conservator or breather. Available in 10kV or 20kV primary (400V/415V secondary), 30–2500kVA, Dyn11 or Yyn0 connection, and ±5% off-circuit tap regulation. Its hermetically sealed design prevents moisture ingress and oil oxidation, extending service life and reducing maintenance, while the grain-oriented silicon steel core delivers 30–40% lower no-load loss than legacy S9 units. The same platform is also offered in S13, S20, and S22 efficiency classes.

10kV / 20kV 30–2500 kVA Fully Sealed Tank Corrugated Wall
20kV
Max HV Voltage
2500kVA
Max Capacity
ONAN
Cooling
IP54
Protection

Fully Sealed Oil-Immersed Transformer with Corrugated-Wall Tank

10kV/20kV, 30–2500kVA, no conservator, maintenance-friendly, low-loss core

The GOHO S11 / S13 / S20 / S22 series is a complete family of three-phase oil-immersed, fully sealed distribution transformers offering four efficiency levels on one platform. All models share the same corrugated-wall fully sealed tank, off-circuit tap changer (±5% in two steps), and a capacity range of 30–2500kVA, available in two primary-voltage models — 10kV and 20kV — allowing customers to select the model that matches their local grid voltage.

The transformer features a fully sealed oil tank with corrugated wall construction for natural cooling, eliminating the need for an oil conservator and breather. This sealed design prevents moisture ingress and oil oxidation, significantly extending service life and reducing maintenance compared to conventional open-breathing transformers.

Built on the same core platform, the four models differ in no-load and load losses, covering the full efficiency spectrum: S11 is the economical entry model for budget-sensitive markets; S13 meets GB 20052-2020 Class 3 efficiency for mainstream grid projects; S20 delivers Class 2 efficiency for long-term operating savings; and S22 achieves the highest Class 1 efficiency with the lowest losses in the series.

  • 10kV / 20kV primary — 400V/415V secondary
  • 30–2500 kVA — dual-voltage split-primary winding
  • Fully sealed corrugated tank — no conservator/breather
  • Dyn11 / Yyn0 — selectable connection group
  • ±5% off-circuit tap — 2-step voltage regulation
  • Low-loss silicon steel core — 30–40% less no-load loss
S11 oil-immersed fully sealed corrugated-wall transformer

Detailed Parameters

Complete technical specifications for S11 oil-immersed distribution transformer

ParameterSpecification
Rated Capacity30 – 2500 kVA
Rated Voltage (HV)10kV or 20kV (two models — specify when ordering)
Rated Voltage (LV)400V (415V optional for export)
Rated Frequency50Hz / 60Hz
Connection GroupDyn11 / Yyn0 (selectable)
Voltage Regulation±5% (off-circuit tap changer, 2 steps)
Cooling MethodONAN (Oil Natural Air Natural) — corrugated wall tank
Insulation LevelLI 75 / AC 35 (HV) / LI 40 / AC 5 (LV)
Transformer TypeOil-immersed, fully sealed, non-excitation voltage regulation
Tank ConstructionFully sealed corrugated wall — no oil conservator or breather
Oil TypeMineral insulating oil (or ester fluid — optional)
Degree of ProtectionIP44 / IP54 (tank and bushings)
Core MaterialGrain-oriented silicon steel (cold-rolled)
No-Load Loss (S11)Baseline — 30–40% lower than legacy S9
Efficiency Class (S11)Legacy / GB/T 6451 entry level
No-Load Loss (S13/S20/S22)≈20% lower / Class 2 / Class 1 (GB 20052-2020)
Ambient Temperature Range-25°C to +40°C
AltitudeUp to 1000m (derating required for higher altitudes)
InstallationPole-mounted or ground-mounted (outdoor)
Impedance VoltagePer GB 1094 / IEC 60076 (per capacity)
Noise Level≤ 55–65 dB(A) (per capacity)
Winding MaterialCopper (aluminum optional)
Service Life≥ 20 years (sealed design extends by 30–50%)
StandardsGB/T 6451, GB 1094, GB 20052-2020, IEC 60076

S11 / S13 / S20 / S22 — Four Efficiency Levels, One Platform

Choose the loss class that fits your budget and local energy standard

ModelEfficiency ClassNo-Load LossBest For
S11Legacy / GB/T 6451Baseline (highest)Budget-sensitive markets, legacy retrofits
S13GB 20052-2020 Class 3≈ 20% lower than S11Mainstream urban & rural grid projects
S20GB 20052-2020 Class 2Lower than S13High-duty-cycle industrial, long operating hours
S22GB 20052-2020 Class 1Lowest in seriesGreen buildings, data centers, mandatory high-efficiency

Why Choose GOHO S11 Transformer

Sealed maintenance-free design, low-loss core, and dual-voltage flexibility

Dual-Voltage 10kV / 20kV Design

A split-primary winding reconfigurable between 10kV and 20kV via the off-circuit tap changer lets one transformer serve both voltage networks — ideal during grid-upgrade programs converting distribution from 10kV to 20kV, eliminating the need for separate transformer inventory for different voltage zones.

Fully Sealed Oil Tank

The corrugated wall tank is hermetically sealed with no oil conservator, breather, or silica-gel dryer — preventing moisture absorption by the insulating oil, eliminating oil oxidation from atmospheric exposure, and stopping sludge and acidic compounds that accelerate insulation degradation. Service life is extended 30–50% over open-breathing designs.

Corrugated Wall Cooling

Tank walls formed from thin steel pressed into corrugated panels expand and contract with oil volume changes while providing efficient natural convection cooling — eliminating separate cooling radiators, reducing overall dimensions, and providing built-in oil expansion compensation without a separate conservator.

Low-Loss Silicon Steel Core

Optimized grain-oriented silicon steel core material, improved core joint design, and reduced flux density achieve no-load losses typically 30–40% lower than legacy S9 series equivalents — delivering measurable energy savings over the transformer's 20+ year service life.

Non-Excitation Voltage Regulation

An off-circuit (de-energized) tap changer provides ±5% voltage regulation in two steps, enabling field adjustment of the voltage ratio to match local distribution network voltage conditions — operates only when de-energized and provides reliable, maintenance-free voltage ratio adjustment.

Reduced Installation Time

The sealed, oil-filled design arrives factory-filled and factory-tested — no on-site oil filling, processing, sampling, or breather installation required, cutting site commissioning time and labor compared to conventional transformers.

Four Efficiency Classes, One Platform

S11, S13, S20, and S22 share identical tank, core, and winding architecture — choose the efficiency level matching your budget and local energy standard without redesigning the installation; spare parts and footprint stay interchangeable across the full series.

Outdoor-Rated Protection

IP44/IP54 protection on tank and bushings makes the S11 suitable for outdoor pole-mounted and ground-mounted installation in urban, rural, and industrial environments, with corrosion-resistant paint and sealed construction for reliable long-term outdoor service.

IEC & GB Compliance

Designed and tested to IEC 60076, GB/T 6451, GB 1094, and GB 20052-2020 — covering power transformers, oil-immersed distribution transformers, and China's energy-efficiency standard. Each unit is factory routine-tested with a full test report supplied.

Where S11 Transformer Excels

Step-down MV/LV transformation across grid, industrial, and infrastructure sectors

Urban & Rural Grid

10kV/20kV pole & ground mount

Industrial Supply

Facility step-down transformers

Residential Complexes

Community power distribution

Infrastructure

Schools, hospitals, public facilities

Grid Upgrades

10kV to 20kV conversion

Oil & Gas Fields

Field distribution power supply

Agriculture

Rural electrification

Commercial

Retail & hospitality supply

Quality & Compliance

Certified to international and Chinese transformer standards

IEC 60076

Power transformers standard

GB 20052-2020

Energy-efficiency standard

GB/T 6451 / GB 1094

Oil-immersed & power transformer

ISO 9001

Quality management certified

Frequently Asked Questions

Common questions about S11 oil-immersed distribution transformers

What is the difference between S11, S13, S20, and S22?

All four share the identical tank, core, and winding architecture — they differ only in no-load and load losses, defining their efficiency class under GB 20052-2020: (1) S11 — legacy/economical entry model, baseline losses, for budget-sensitive markets and legacy grid retrofits. (2) S13 — GB 20052-2020 Class 3, ≈20% lower no-load loss than S11, for mainstream urban and rural grid projects. (3) S20 — GB 20052-2020 Class 2, lower losses still, for high-duty-cycle industrial sites and long operating hours. (4) S22 — GB 20052-2020 Class 1, lowest losses in the series, for green buildings, data centers, and regions with mandatory high-efficiency standards. Exact loss values (W) for each capacity follow GB 20052-2020 Table 1; contact us for the type-test report of your required capacity. The physical footprint and spare parts are identical across all four, so upgrading from S11 to S13/S20/S22 does not change the installation.

How does the fully sealed corrugated-wall tank work without a conservator?

Conventional oil-immersed transformers use an oil conservator (a reservoir above the tank) and a breather with silica gel to accommodate oil expansion/contraction with temperature while keeping air out. The S11 eliminates both: (1) The tank walls are pressed from thin steel into corrugated panels — these panels flex outward as the oil heats and expands, and contract inward as it cools, providing built-in volume compensation. (2) The entire tank is hermetically sealed (welded, no gaskets exposed to atmosphere), so the oil never contacts outside air. (3) This prevents moisture absorption (which lowers dielectric strength) and oil oxidation (which forms sludge and acids that degrade insulation). (4) The corrugated panels also act as cooling fins, increasing surface area for natural convection (ONAN) without separate radiators. The result is a more compact, maintenance-free transformer with 30–50% longer service life compared to open-breathing conservator-type designs.

Can the S11 operate on both 10kV and 20kV networks?

Yes. The S11 primary (HV) winding has a split configuration that can be reconfigured between 10kV and 20kV operation via the off-circuit tap changer. This means: (1) One transformer can be specified that will work on either a 10kV or 20kV distribution network, reducing the need to stock two separate transformer models for different voltage zones. (2) It is especially valuable during grid-upgrade programs where distribution networks are progressively converted from 10kV to 20kV — the same transformer can be re-tapped at the new voltage rather than replaced. (3) The voltage change is performed by the off-circuit tap changer, which requires the transformer to be de-energized and locked out before adjustment. (4) Note that the ±5% tap regulation is separate from the 10kV/20kV selection — the ±5% provides fine voltage adjustment within the selected primary voltage level to match local network conditions. Always confirm the primary voltage and tap positions with the utility and have qualified personnel perform any tap-changer adjustment.

Is the S11 suitable for outdoor installation?

Yes — the S11 is designed for outdoor pole-mounted or ground-mounted installation: (1) Protection rating — IP44/IP54 on the tank and bushings, suitable for direct exposure to rain, snow, and dust. (2) Corrosion resistance — the tank uses corrosion-resistant paint suitable for outdoor service; for coastal or highly corrosive environments, special anti-corrosion paint can be specified. (3) Temperature range — -25°C to +40°C ambient; for lower temperatures (e.g., -45°C) we can supply transformer oil with a suitable low-temperature pour point. (4) Altitude — rated up to 1000m; above 1000m, derating of the rated capacity is required per IEC 60076 (typically about 1% per 100m above 1000m) due to reduced air cooling, so confirm your altitude when ordering. (5) For enclosed substations (indoor kiosks) the S11 can also be installed inside a YBM prefabricated substation enclosure. Always follow local utility and installation regulations for spacing, clearances, and protective devices.

What capacity and connection group should I choose?

Capacity (30–2500 kVA) and connection group (Dyn11 or Yyn0) depend on your load and network: (1) Capacity — select based on the total connected load with a 20–30% margin for future growth; for example, a 500 kVA transformer serves roughly 400 kW of load at 0.8 power factor. For fluctuating loads or motor starts, consider oversizing. (2) Dyn11 — HV delta, LV star with neutral brought out; provides 3-phase + neutral (400V/230V), better harmonic suppression, and is the most common choice for commercial/residential mixed single-phase/three-phase loads. (3) Yyn0 — HV star, LV star with neutral; suitable for mostly balanced three-phase loads and where the utility requires a star primary. Dyn11 is generally preferred for modern distribution. (4) Also specify: HV voltage (10kV or 20kV), LV voltage (400V or 415V), frequency (50Hz or 60Hz), winding material (copper or aluminum), and efficiency class (S11/S13/S20/S22). Provide your single-line diagram and we will recommend the optimal configuration.

What maintenance does the S11 require compared to a conservator-type transformer?

The S11's fully sealed design substantially reduces maintenance compared to conventional conservator-type transformers: (1) No oil conservator, breather, or silica gel — eliminates the need for periodic silica gel replacement, conservator oil-level checks, and breather cleaning. (2) Sealed oil — no moisture ingress or oxidation means oil does not need periodic testing or replacement under normal conditions (recommended oil sample check every 5–10 years for large units, vs. annually for open-breathing types). (3) No sludge/acid formation — insulation degradation is slowed. (4) Installation — arrives factory-filled and tested, so no on-site oil filling, processing, or sampling. (5) Recommended maintenance for the S11: periodic visual inspection of the tank, bushings, and paint; check tightness of bolted connections; verify tap-changer position; clean bushings; and inspect the grounding connection. Because the oil is sealed, there is no routine oil top-up. The expected service life is ≥20 years, with the sealed design extending it by 30–50% over open-breathing designs.

Reliable Sealed Oil-Immersed Distribution Transformer

Tell us your required capacity (30–2500 kVA), primary voltage (10kV or 20kV), secondary voltage (400V or 415V), connection group (Dyn11 or Yyn0), efficiency class (S11/S13/S20/S22), winding material (copper or aluminum), and installation environment. We'll configure the right transformer and provide a factory quote in 24 hours.