XGN2-12(Z) Fixed Type AC Metal-Enclosed Switchgear
GOHO XGN2-12(Z) box-type fixed AC metal-enclosed switchgear — 3.6–12kV, 630–3150A, fixed-mounting MV distribution panel with vacuum circuit breaker and spring operating mechanism. Supports single bus, double bus, and single bus with bypass configurations. Robust, reliable, and cost-effective for substations, power plants, and industrial power systems.
Proven Fixed-Type MV Switchgear
Simple, robust, and reliable — the workhorse of medium-voltage power distribution for decades.
Fixed-Mounting Design for Maximum Reliability
The XGN2-12(Z) is a box-type fixed AC metal-enclosed switchgear designed for three-phase AC power systems operating at 3.6–12kV and 50Hz. It serves as the primary switchgear panel for receiving and distributing electrical energy in substations, power plants, and industrial facilities.
Unlike withdrawable or draw-out alternatives, the XGN2-12 uses a fixed-mounting configuration where all main components — vacuum circuit breaker, disconnector, current transformers, voltage transformers, and protective relays — are permanently installed within a metal-enclosed earthed steel frame. This design eliminates moving carriages and draw-out mechanisms, resulting in fewer mechanical parts, simpler interlocking, higher long-term reliability, and lower maintenance requirements over the equipment lifecycle.
The cabinet body is constructed from high-strength steel plates with electrostatic spray-powder coating, providing excellent corrosion resistance and mechanical protection. The panel door features mechanical interlocks linked to the disconnector and circuit breaker, ensuring safe operating sequences in full compliance with IEC 62271-200. Available in single bus, double bus, and single bus with bypass configurations to suit any substation topology.
- Voltage range: 3.6kV / 7.2kV / 12kV — covers standard MV distribution levels
- Current range: 630A to 3150A main busbar — scalable for any load
- Short-circuit ratings: 25kA / 31.5kA / 40kA (4s) — meets utility standards
- Vacuum circuit breaker (ZN series) with spring operating mechanism
- Supports single bus, double bus, and single bus with bypass systems
- Clear compartmentalization: busbar, breaker, and cable compartments
- Mechanical interlocking prevents incorrect operation sequences
- Arc-resistant design with pressure-relief channels for safety
- IP3X / IP4X enclosure protection — dust and accidental contact safe
- Proven field performance across thousands of installations

XGN2-12 Switchgear Specifications
Complete technical parameters for the fixed-type metal-enclosed medium voltage switchgear.
| Rated Voltage | 3.6kV / 7.2kV / 12kV |
|---|---|
| Rated Insulation Voltage | 12kV |
| Rated Frequency | 50Hz / 60Hz |
| Rated Current (Main Busbar) | 630A – 3150A |
| Rated Short-Time Withstand (Icw) | 25kA / 31.5kA / 40kA (4 seconds) |
| Rated Peak Withstand (Ipk) | 63kA / 80kA / 100kA |
| Busbar System | Single bus / Double bus / Single bus with bypass |
| Installation Type | Fixed mounting (non-drawout) |
| Circuit Breaker Type | Vacuum circuit breaker (ZN series) |
| Operating Mechanism | Spring-operated mechanism — manual or motor-charged |
| Disconnector | Integrated high-voltage disconnector with earthing switch |
| Instrument Transformers | Current transformers (CT) & voltage transformers (VT) — cast resin |
| Protection Relays | Numerical or electromechanical relays — configurable per scheme |
| Degree of Protection | IP3X / IP4X (enclosure) |
| Arc Resistance | Internal arc fault containment with pressure relief channels |
| Mechanical Endurance | ≥ 10,000 operations |
| Panel Dimensions (W×D×H) | 1100 × 1200 × 2800 mm (standard scheme) |
| Cabinet Material | High-strength steel plate with electrostatic spray-powder coating |
| Ambient Temperature | -10°C ~ +40°C (indoor installation) |
| Altitude | ≤ 1000m above sea level |
| Applicable Standards | IEC 62271-200, GB 3906 |
Built for Reliability & Long Service Life
Fixed-mount design means fewer moving parts, simpler interlocking, and decades of dependable service.
Fixed-Mount Reliability
No moving carriages or draw-out mechanisms — fewer parts means higher reliability and lower lifetime maintenance costs.
Flexible Busbar Configs
Supports single bus, double bus, and single bus with bypass systems — adaptable to any substation topology.
Cost-Effective Solution
Lower initial capital expenditure than withdrawable switchgear, with reduced lifetime maintenance — ideal for standard distribution projects.
Mechanical Interlocking
Panel door interlocked with disconnector and breaker — prevents incorrect operations and ensures safe maintenance access.
Arc-Resistant Design
Pressure-relief channels and arc containment features mitigate internal arc fault effects — compliant with IEC 62271-200.
Clear Compartmentalization
Logical separation between busbar, circuit breaker, and cable compartments — safe inspection and routine maintenance.
Proven Field Performance
One of the most widely deployed fixed-type MV switchgear models — decades of reliable operation across thousands of installations.
Vacuum Interruption
ZN series vacuum circuit breaker with spring mechanism — long electrical life, maintenance-free contacts, safe interruption.
Corrosion Resistant
High-strength steel with electrostatic spray-powder coating — excellent corrosion resistance for long cabinet life.
Where XGN2-12 Excels
The versatile workhorse of medium-voltage distribution — deployed across power generation, transmission, and industry.
Urban & Rural Substations
Primary MV distribution switchgear
Power Plants
Thermal & hydro plant auxiliary power
Industrial & Mining
Process power supply for factories & mines
Commercial Buildings
MV distribution for large public buildings
Infrastructure
Railways, airports, hospitals
Oil & Gas Fields
Upstream & midstream power systems
Certified to International Standards
Manufactured and tested in compliance with global switchgear safety and performance standards.
Test
Frequently Asked Questions
Common questions about fixed-type medium voltage switchgear. Need a custom scheme? Our engineers can help.
The main difference is in how the circuit breaker is installed and accessed. Fixed-type switchgear (like XGN2-12) has all components permanently mounted inside the cabinet — the breaker, disconnector, CT/VT, and relays are all bolted in place. Withdrawable (draw-out) switchgear uses a removable breaker carriage that can be slid out for maintenance or replacement. Fixed-type is simpler, more robust, lower cost, and has fewer parts to maintain — ideal for standard distribution where you don't need frequent breaker swapping. Withdrawable is more flexible for critical applications where you need to swap a breaker quickly to minimize downtime, but it's more expensive and has more complex interlocking. For most utility distribution and industrial applications, fixed-type is the reliable, cost-effective choice.
The short-circuit rating (Icw) should be based on the maximum prospective short-circuit current at the point where the switchgear is installed. This depends on the system voltage, transformer capacity, impedance, and the fault level contributed by upstream sources. Our XGN2-12 is available in 25kA, 31.5kA, and 40kA ratings (4-second). As a general guide: 25kA for smaller substations and distribution networks fed by moderate transformers; 31.5kA for most standard 12kV distribution substations; 40kA for locations close to large power transformers or generation sources where fault levels are high. Send us your single-line diagram or system parameters and we'll calculate the required rating for your specific application.
It depends on your reliability requirements and operational flexibility needs. Single bus is the simplest and most economical — all feeders connect to one busbar. Good for standard distribution where planned outages during bus maintenance are acceptable. Single bus with bypass adds a bypass busbar that allows you to maintain or replace a breaker without interrupting the feeder — achieved by bypassing the breaker through the disconnector. Better for critical feeders. Double bus has two independent busbars with a bus coupler — each feeder can be switched to either bus. This provides the highest availability because you can take one bus completely out of service for maintenance while all feeders continue operating on the other bus. Required for substations with high uptime requirements. We'll recommend the optimal configuration based on your project's reliability needs and budget.
The standard XGN2-12 is designed for indoor installation with IP3X or IP4X protection. It's intended for use inside a substation building or equipment room where it's protected from direct weather exposure. The operating temperature range is -10°C to +40°C, and it should be installed at altitudes below 1000m (derating applies above that). For outdoor applications, we recommend our pad-mounted substation or kiosk-type substation products (like the ZBW or YBM series), which are specifically designed for outdoor use with higher IP ratings (IP33, IP44, or IP54) and weather-resistant enclosures. Alternatively, we can provide a custom outdoor enclosure or containerized solution housing the XGN2-12 switchgear inside. Contact us to discuss your specific installation environment.
The XGN2-12 can be equipped with various protection relay options depending on your requirements. Standard offerings include: electromechanical relays for basic overcurrent and earth fault protection (cost-effective for simple schemes); numerical/microprocessor-based relays for comprehensive protection with metering, communication, and advanced features; and dedicated feeder protection, transformer protection, motor protection, or busbar protection relays as needed. We can supply relays from major brands or our own GOHO branded relays. Common protection functions include: overcurrent (50/51), earth fault (50N/51N), overvoltage (59), undervoltage (27), directional overcurrent (67), and more. All relays are pre-wired and tested in the factory before shipment. Let us know your protection requirements and we'll configure the relay scheme accordingly.
One of the key advantages of fixed-type switchgear is its low maintenance requirement. Because there are no moving carriages or draw-out mechanisms, there are fewer parts to maintain. Typical maintenance tasks include: annual visual inspection of the cabinet, busbar connections, and insulation; periodic cleaning of internal compartments (every 2-3 years); mechanical operation check of disconnector and earthing switch (annually); spring mechanism lubrication and condition check (every 3-5 years); vacuum breaker contact wear monitoring (based on operation count — typically 10,000+ mechanical operations); and relay calibration and testing (every 2-5 years per utility standards). Compared to withdrawable switchgear, which requires regular carriage mechanism maintenance and racking gear inspection, the fixed-type design significantly reduces long-term maintenance costs and downtime. We provide detailed maintenance manuals with every shipment.
Complete MV & LV Switchgear Range
From medium voltage switchgear to low voltage distribution — one supplier for your entire electrical room.
Configure Your Switchgear Panel
Send us your single-line diagram and protection requirements. Get a customized XGN2-12 panel with the right rating, scheme, and relays.
Get a Project Quote