XGN2-12 Switchgear

XGN2-12 Fixed Type Metal-Enclosed Switchgear | 12kV MV Distribution Panel | GOHO
GOHO XGN2-12 fixed type metal-enclosed medium voltage switchgear panel
Medium Voltage

XGN2-12(Z) Fixed Type AC Metal-Enclosed Switchgear

GOHO XGN2-12(Z) box-type fixed AC metal-enclosed switchgear — 3.6–12kV, 630–3150A, fixed-mounting MV distribution panel with vacuum circuit breaker and spring operating mechanism. Supports single bus, double bus, and single bus with bypass configurations. Robust, reliable, and cost-effective for substations, power plants, and industrial power systems.

3.6–12kV Rated Fixed-Mount Design 630–3150A Arc-Resistant
12kV
Max Voltage
3150A
Max Current
40kA
Short-Time (4s)
10,000
Mechanical Ops

Proven Fixed-Type MV Switchgear

Simple, robust, and reliable — the workhorse of medium-voltage power distribution for decades.

Fixed-Mounting Design for Maximum Reliability

The XGN2-12(Z) is a box-type fixed AC metal-enclosed switchgear designed for three-phase AC power systems operating at 3.6–12kV and 50Hz. It serves as the primary switchgear panel for receiving and distributing electrical energy in substations, power plants, and industrial facilities.

Unlike withdrawable or draw-out alternatives, the XGN2-12 uses a fixed-mounting configuration where all main components — vacuum circuit breaker, disconnector, current transformers, voltage transformers, and protective relays — are permanently installed within a metal-enclosed earthed steel frame. This design eliminates moving carriages and draw-out mechanisms, resulting in fewer mechanical parts, simpler interlocking, higher long-term reliability, and lower maintenance requirements over the equipment lifecycle.

The cabinet body is constructed from high-strength steel plates with electrostatic spray-powder coating, providing excellent corrosion resistance and mechanical protection. The panel door features mechanical interlocks linked to the disconnector and circuit breaker, ensuring safe operating sequences in full compliance with IEC 62271-200. Available in single bus, double bus, and single bus with bypass configurations to suit any substation topology.

  • Voltage range: 3.6kV / 7.2kV / 12kV — covers standard MV distribution levels
  • Current range: 630A to 3150A main busbar — scalable for any load
  • Short-circuit ratings: 25kA / 31.5kA / 40kA (4s) — meets utility standards
  • Vacuum circuit breaker (ZN series) with spring operating mechanism
  • Supports single bus, double bus, and single bus with bypass systems
  • Clear compartmentalization: busbar, breaker, and cable compartments
  • Mechanical interlocking prevents incorrect operation sequences
  • Arc-resistant design with pressure-relief channels for safety
  • IP3X / IP4X enclosure protection — dust and accidental contact safe
  • Proven field performance across thousands of installations
XGN2-12 fixed type metal-enclosed switchgear with protection relay

XGN2-12 Switchgear Specifications

Complete technical parameters for the fixed-type metal-enclosed medium voltage switchgear.

Rated Voltage3.6kV / 7.2kV / 12kV
Rated Insulation Voltage12kV
Rated Frequency50Hz / 60Hz
Rated Current (Main Busbar)630A – 3150A
Rated Short-Time Withstand (Icw)25kA / 31.5kA / 40kA (4 seconds)
Rated Peak Withstand (Ipk)63kA / 80kA / 100kA
Busbar SystemSingle bus / Double bus / Single bus with bypass
Installation TypeFixed mounting (non-drawout)
Circuit Breaker TypeVacuum circuit breaker (ZN series)
Operating MechanismSpring-operated mechanism — manual or motor-charged
DisconnectorIntegrated high-voltage disconnector with earthing switch
Instrument TransformersCurrent transformers (CT) & voltage transformers (VT) — cast resin
Protection RelaysNumerical or electromechanical relays — configurable per scheme
Degree of ProtectionIP3X / IP4X (enclosure)
Arc ResistanceInternal arc fault containment with pressure relief channels
Mechanical Endurance≥ 10,000 operations
Panel Dimensions (W×D×H)1100 × 1200 × 2800 mm (standard scheme)
Cabinet MaterialHigh-strength steel plate with electrostatic spray-powder coating
Ambient Temperature-10°C ~ +40°C (indoor installation)
Altitude≤ 1000m above sea level
Applicable StandardsIEC 62271-200, GB 3906

Built for Reliability & Long Service Life

Fixed-mount design means fewer moving parts, simpler interlocking, and decades of dependable service.

Fixed-Mount Reliability

No moving carriages or draw-out mechanisms — fewer parts means higher reliability and lower lifetime maintenance costs.

Flexible Busbar Configs

Supports single bus, double bus, and single bus with bypass systems — adaptable to any substation topology.

Cost-Effective Solution

Lower initial capital expenditure than withdrawable switchgear, with reduced lifetime maintenance — ideal for standard distribution projects.

Mechanical Interlocking

Panel door interlocked with disconnector and breaker — prevents incorrect operations and ensures safe maintenance access.

Arc-Resistant Design

Pressure-relief channels and arc containment features mitigate internal arc fault effects — compliant with IEC 62271-200.

Clear Compartmentalization

Logical separation between busbar, circuit breaker, and cable compartments — safe inspection and routine maintenance.

Proven Field Performance

One of the most widely deployed fixed-type MV switchgear models — decades of reliable operation across thousands of installations.

Vacuum Interruption

ZN series vacuum circuit breaker with spring mechanism — long electrical life, maintenance-free contacts, safe interruption.

Corrosion Resistant

High-strength steel with electrostatic spray-powder coating — excellent corrosion resistance for long cabinet life.

Where XGN2-12 Excels

The versatile workhorse of medium-voltage distribution — deployed across power generation, transmission, and industry.

Urban & Rural Substations

Primary MV distribution switchgear

Power Plants

Thermal & hydro plant auxiliary power

Industrial & Mining

Process power supply for factories & mines

Commercial Buildings

MV distribution for large public buildings

Infrastructure

Railways, airports, hospitals

Oil & Gas Fields

Upstream & midstream power systems

Certified to International Standards

Manufactured and tested in compliance with global switchgear safety and performance standards.

IEC
IEC 62271-200
AC Metal-Enclosed Switchgear
GB
GB 3906
3-35kV AC Metal Switchgear
IP4X
IP4X Rated
Dust & Finger Protected
Type
Test
Type-Tested
Full dielectric & thermal tests

Frequently Asked Questions

Common questions about fixed-type medium voltage switchgear. Need a custom scheme? Our engineers can help.

What's the difference between fixed-type and withdrawable switchgear?

The main difference is in how the circuit breaker is installed and accessed. Fixed-type switchgear (like XGN2-12) has all components permanently mounted inside the cabinet — the breaker, disconnector, CT/VT, and relays are all bolted in place. Withdrawable (draw-out) switchgear uses a removable breaker carriage that can be slid out for maintenance or replacement. Fixed-type is simpler, more robust, lower cost, and has fewer parts to maintain — ideal for standard distribution where you don't need frequent breaker swapping. Withdrawable is more flexible for critical applications where you need to swap a breaker quickly to minimize downtime, but it's more expensive and has more complex interlocking. For most utility distribution and industrial applications, fixed-type is the reliable, cost-effective choice.

How do I determine the right short-circuit rating for my project?

The short-circuit rating (Icw) should be based on the maximum prospective short-circuit current at the point where the switchgear is installed. This depends on the system voltage, transformer capacity, impedance, and the fault level contributed by upstream sources. Our XGN2-12 is available in 25kA, 31.5kA, and 40kA ratings (4-second). As a general guide: 25kA for smaller substations and distribution networks fed by moderate transformers; 31.5kA for most standard 12kV distribution substations; 40kA for locations close to large power transformers or generation sources where fault levels are high. Send us your single-line diagram or system parameters and we'll calculate the required rating for your specific application.

What busbar configuration should I choose?

It depends on your reliability requirements and operational flexibility needs. Single bus is the simplest and most economical — all feeders connect to one busbar. Good for standard distribution where planned outages during bus maintenance are acceptable. Single bus with bypass adds a bypass busbar that allows you to maintain or replace a breaker without interrupting the feeder — achieved by bypassing the breaker through the disconnector. Better for critical feeders. Double bus has two independent busbars with a bus coupler — each feeder can be switched to either bus. This provides the highest availability because you can take one bus completely out of service for maintenance while all feeders continue operating on the other bus. Required for substations with high uptime requirements. We'll recommend the optimal configuration based on your project's reliability needs and budget.

Is the XGN2-12 suitable for outdoor installation?

The standard XGN2-12 is designed for indoor installation with IP3X or IP4X protection. It's intended for use inside a substation building or equipment room where it's protected from direct weather exposure. The operating temperature range is -10°C to +40°C, and it should be installed at altitudes below 1000m (derating applies above that). For outdoor applications, we recommend our pad-mounted substation or kiosk-type substation products (like the ZBW or YBM series), which are specifically designed for outdoor use with higher IP ratings (IP33, IP44, or IP54) and weather-resistant enclosures. Alternatively, we can provide a custom outdoor enclosure or containerized solution housing the XGN2-12 switchgear inside. Contact us to discuss your specific installation environment.

What protection relay options are available?

The XGN2-12 can be equipped with various protection relay options depending on your requirements. Standard offerings include: electromechanical relays for basic overcurrent and earth fault protection (cost-effective for simple schemes); numerical/microprocessor-based relays for comprehensive protection with metering, communication, and advanced features; and dedicated feeder protection, transformer protection, motor protection, or busbar protection relays as needed. We can supply relays from major brands or our own GOHO branded relays. Common protection functions include: overcurrent (50/51), earth fault (50N/51N), overvoltage (59), undervoltage (27), directional overcurrent (67), and more. All relays are pre-wired and tested in the factory before shipment. Let us know your protection requirements and we'll configure the relay scheme accordingly.

What maintenance does fixed-type switchgear require?

One of the key advantages of fixed-type switchgear is its low maintenance requirement. Because there are no moving carriages or draw-out mechanisms, there are fewer parts to maintain. Typical maintenance tasks include: annual visual inspection of the cabinet, busbar connections, and insulation; periodic cleaning of internal compartments (every 2-3 years); mechanical operation check of disconnector and earthing switch (annually); spring mechanism lubrication and condition check (every 3-5 years); vacuum breaker contact wear monitoring (based on operation count — typically 10,000+ mechanical operations); and relay calibration and testing (every 2-5 years per utility standards). Compared to withdrawable switchgear, which requires regular carriage mechanism maintenance and racking gear inspection, the fixed-type design significantly reduces long-term maintenance costs and downtime. We provide detailed maintenance manuals with every shipment.

Configure Your Switchgear Panel

Send us your single-line diagram and protection requirements. Get a customized XGN2-12 panel with the right rating, scheme, and relays.

Get a Project Quote
Scroll to Top