S11 Oil-Immersed Distribution Transformer
The GOHO S11 series is a three-phase oil-immersed, fully sealed distribution transformer with a corrugated-wall tank and no oil conservator or breather. Available in 10kV or 20kV primary (400V/415V secondary), 30–2500kVA, Dyn11 or Yyn0 connection, and ±5% off-circuit tap regulation. Its hermetically sealed design prevents moisture ingress and oil oxidation, extending service life and reducing maintenance, while the grain-oriented silicon steel core delivers 30–40% lower no-load loss than legacy S9 units. The same platform is also offered in S13, S20, and S22 efficiency classes.
Fully Sealed Oil-Immersed Transformer with Corrugated-Wall Tank
10kV/20kV, 30–2500kVA, no conservator, maintenance-friendly, low-loss core
The GOHO S11 / S13 / S20 / S22 series is a complete family of three-phase oil-immersed, fully sealed distribution transformers offering four efficiency levels on one platform. All models share the same corrugated-wall fully sealed tank, off-circuit tap changer (±5% in two steps), and a capacity range of 30–2500kVA, available in two primary-voltage models — 10kV and 20kV — allowing customers to select the model that matches their local grid voltage.
The transformer features a fully sealed oil tank with corrugated wall construction for natural cooling, eliminating the need for an oil conservator and breather. This sealed design prevents moisture ingress and oil oxidation, significantly extending service life and reducing maintenance compared to conventional open-breathing transformers.
Built on the same core platform, the four models differ in no-load and load losses, covering the full efficiency spectrum: S11 is the economical entry model for budget-sensitive markets; S13 meets GB 20052-2020 Class 3 efficiency for mainstream grid projects; S20 delivers Class 2 efficiency for long-term operating savings; and S22 achieves the highest Class 1 efficiency with the lowest losses in the series.
- 10kV / 20kV primary — 400V/415V secondary
- 30–2500 kVA — dual-voltage split-primary winding
- Fully sealed corrugated tank — no conservator/breather
- Dyn11 / Yyn0 — selectable connection group
- ±5% off-circuit tap — 2-step voltage regulation
- Low-loss silicon steel core — 30–40% less no-load loss

Detailed Parameters
Complete technical specifications for S11 oil-immersed distribution transformer
| Parameter | Specification |
|---|---|
| Rated Capacity | 30 – 2500 kVA |
| Rated Voltage (HV) | 10kV or 20kV (two models — specify when ordering) |
| Rated Voltage (LV) | 400V (415V optional for export) |
| Rated Frequency | 50Hz / 60Hz |
| Connection Group | Dyn11 / Yyn0 (selectable) |
| Voltage Regulation | ±5% (off-circuit tap changer, 2 steps) |
| Cooling Method | ONAN (Oil Natural Air Natural) — corrugated wall tank |
| Insulation Level | LI 75 / AC 35 (HV) / LI 40 / AC 5 (LV) |
| Transformer Type | Oil-immersed, fully sealed, non-excitation voltage regulation |
| Tank Construction | Fully sealed corrugated wall — no oil conservator or breather |
| Oil Type | Mineral insulating oil (or ester fluid — optional) |
| Degree of Protection | IP44 / IP54 (tank and bushings) |
| Core Material | Grain-oriented silicon steel (cold-rolled) |
| No-Load Loss (S11) | Baseline — 30–40% lower than legacy S9 |
| Efficiency Class (S11) | Legacy / GB/T 6451 entry level |
| No-Load Loss (S13/S20/S22) | ≈20% lower / Class 2 / Class 1 (GB 20052-2020) |
| Ambient Temperature Range | -25°C to +40°C |
| Altitude | Up to 1000m (derating required for higher altitudes) |
| Installation | Pole-mounted or ground-mounted (outdoor) |
| Impedance Voltage | Per GB 1094 / IEC 60076 (per capacity) |
| Noise Level | ≤ 55–65 dB(A) (per capacity) |
| Winding Material | Copper (aluminum optional) |
| Service Life | ≥ 20 years (sealed design extends by 30–50%) |
| Standards | GB/T 6451, GB 1094, GB 20052-2020, IEC 60076 |
S11 / S13 / S20 / S22 — Four Efficiency Levels, One Platform
Choose the loss class that fits your budget and local energy standard
| Model | Efficiency Class | No-Load Loss | Best For |
|---|---|---|---|
| S11 | Legacy / GB/T 6451 | Baseline (highest) | Budget-sensitive markets, legacy retrofits |
| S13 | GB 20052-2020 Class 3 | ≈ 20% lower than S11 | Mainstream urban & rural grid projects |
| S20 | GB 20052-2020 Class 2 | Lower than S13 | High-duty-cycle industrial, long operating hours |
| S22 | GB 20052-2020 Class 1 | Lowest in series | Green buildings, data centers, mandatory high-efficiency |
Why Choose GOHO S11 Transformer
Sealed maintenance-free design, low-loss core, and dual-voltage flexibility
Dual-Voltage 10kV / 20kV Design
A split-primary winding reconfigurable between 10kV and 20kV via the off-circuit tap changer lets one transformer serve both voltage networks — ideal during grid-upgrade programs converting distribution from 10kV to 20kV, eliminating the need for separate transformer inventory for different voltage zones.
Fully Sealed Oil Tank
The corrugated wall tank is hermetically sealed with no oil conservator, breather, or silica-gel dryer — preventing moisture absorption by the insulating oil, eliminating oil oxidation from atmospheric exposure, and stopping sludge and acidic compounds that accelerate insulation degradation. Service life is extended 30–50% over open-breathing designs.
Corrugated Wall Cooling
Tank walls formed from thin steel pressed into corrugated panels expand and contract with oil volume changes while providing efficient natural convection cooling — eliminating separate cooling radiators, reducing overall dimensions, and providing built-in oil expansion compensation without a separate conservator.
Low-Loss Silicon Steel Core
Optimized grain-oriented silicon steel core material, improved core joint design, and reduced flux density achieve no-load losses typically 30–40% lower than legacy S9 series equivalents — delivering measurable energy savings over the transformer's 20+ year service life.
Non-Excitation Voltage Regulation
An off-circuit (de-energized) tap changer provides ±5% voltage regulation in two steps, enabling field adjustment of the voltage ratio to match local distribution network voltage conditions — operates only when de-energized and provides reliable, maintenance-free voltage ratio adjustment.
Reduced Installation Time
The sealed, oil-filled design arrives factory-filled and factory-tested — no on-site oil filling, processing, sampling, or breather installation required, cutting site commissioning time and labor compared to conventional transformers.
Four Efficiency Classes, One Platform
S11, S13, S20, and S22 share identical tank, core, and winding architecture — choose the efficiency level matching your budget and local energy standard without redesigning the installation; spare parts and footprint stay interchangeable across the full series.
Outdoor-Rated Protection
IP44/IP54 protection on tank and bushings makes the S11 suitable for outdoor pole-mounted and ground-mounted installation in urban, rural, and industrial environments, with corrosion-resistant paint and sealed construction for reliable long-term outdoor service.
IEC & GB Compliance
Designed and tested to IEC 60076, GB/T 6451, GB 1094, and GB 20052-2020 — covering power transformers, oil-immersed distribution transformers, and China's energy-efficiency standard. Each unit is factory routine-tested with a full test report supplied.
Where S11 Transformer Excels
Step-down MV/LV transformation across grid, industrial, and infrastructure sectors
Urban & Rural Grid
10kV/20kV pole & ground mount
Industrial Supply
Facility step-down transformers
Residential Complexes
Community power distribution
Infrastructure
Schools, hospitals, public facilities
Grid Upgrades
10kV to 20kV conversion
Oil & Gas Fields
Field distribution power supply
Agriculture
Rural electrification
Commercial
Retail & hospitality supply
Quality & Compliance
Certified to international and Chinese transformer standards
IEC 60076
Power transformers standard
GB 20052-2020
Energy-efficiency standard
GB/T 6451 / GB 1094
Oil-immersed & power transformer
ISO 9001
Quality management certified
Frequently Asked Questions
Common questions about S11 oil-immersed distribution transformers
All four share the identical tank, core, and winding architecture — they differ only in no-load and load losses, defining their efficiency class under GB 20052-2020: (1) S11 — legacy/economical entry model, baseline losses, for budget-sensitive markets and legacy grid retrofits. (2) S13 — GB 20052-2020 Class 3, ≈20% lower no-load loss than S11, for mainstream urban and rural grid projects. (3) S20 — GB 20052-2020 Class 2, lower losses still, for high-duty-cycle industrial sites and long operating hours. (4) S22 — GB 20052-2020 Class 1, lowest losses in the series, for green buildings, data centers, and regions with mandatory high-efficiency standards. Exact loss values (W) for each capacity follow GB 20052-2020 Table 1; contact us for the type-test report of your required capacity. The physical footprint and spare parts are identical across all four, so upgrading from S11 to S13/S20/S22 does not change the installation.
Conventional oil-immersed transformers use an oil conservator (a reservoir above the tank) and a breather with silica gel to accommodate oil expansion/contraction with temperature while keeping air out. The S11 eliminates both: (1) The tank walls are pressed from thin steel into corrugated panels — these panels flex outward as the oil heats and expands, and contract inward as it cools, providing built-in volume compensation. (2) The entire tank is hermetically sealed (welded, no gaskets exposed to atmosphere), so the oil never contacts outside air. (3) This prevents moisture absorption (which lowers dielectric strength) and oil oxidation (which forms sludge and acids that degrade insulation). (4) The corrugated panels also act as cooling fins, increasing surface area for natural convection (ONAN) without separate radiators. The result is a more compact, maintenance-free transformer with 30–50% longer service life compared to open-breathing conservator-type designs.
Yes. The S11 primary (HV) winding has a split configuration that can be reconfigured between 10kV and 20kV operation via the off-circuit tap changer. This means: (1) One transformer can be specified that will work on either a 10kV or 20kV distribution network, reducing the need to stock two separate transformer models for different voltage zones. (2) It is especially valuable during grid-upgrade programs where distribution networks are progressively converted from 10kV to 20kV — the same transformer can be re-tapped at the new voltage rather than replaced. (3) The voltage change is performed by the off-circuit tap changer, which requires the transformer to be de-energized and locked out before adjustment. (4) Note that the ±5% tap regulation is separate from the 10kV/20kV selection — the ±5% provides fine voltage adjustment within the selected primary voltage level to match local network conditions. Always confirm the primary voltage and tap positions with the utility and have qualified personnel perform any tap-changer adjustment.
Yes — the S11 is designed for outdoor pole-mounted or ground-mounted installation: (1) Protection rating — IP44/IP54 on the tank and bushings, suitable for direct exposure to rain, snow, and dust. (2) Corrosion resistance — the tank uses corrosion-resistant paint suitable for outdoor service; for coastal or highly corrosive environments, special anti-corrosion paint can be specified. (3) Temperature range — -25°C to +40°C ambient; for lower temperatures (e.g., -45°C) we can supply transformer oil with a suitable low-temperature pour point. (4) Altitude — rated up to 1000m; above 1000m, derating of the rated capacity is required per IEC 60076 (typically about 1% per 100m above 1000m) due to reduced air cooling, so confirm your altitude when ordering. (5) For enclosed substations (indoor kiosks) the S11 can also be installed inside a YBM prefabricated substation enclosure. Always follow local utility and installation regulations for spacing, clearances, and protective devices.
Capacity (30–2500 kVA) and connection group (Dyn11 or Yyn0) depend on your load and network: (1) Capacity — select based on the total connected load with a 20–30% margin for future growth; for example, a 500 kVA transformer serves roughly 400 kW of load at 0.8 power factor. For fluctuating loads or motor starts, consider oversizing. (2) Dyn11 — HV delta, LV star with neutral brought out; provides 3-phase + neutral (400V/230V), better harmonic suppression, and is the most common choice for commercial/residential mixed single-phase/three-phase loads. (3) Yyn0 — HV star, LV star with neutral; suitable for mostly balanced three-phase loads and where the utility requires a star primary. Dyn11 is generally preferred for modern distribution. (4) Also specify: HV voltage (10kV or 20kV), LV voltage (400V or 415V), frequency (50Hz or 60Hz), winding material (copper or aluminum), and efficiency class (S11/S13/S20/S22). Provide your single-line diagram and we will recommend the optimal configuration.
The S11's fully sealed design substantially reduces maintenance compared to conventional conservator-type transformers: (1) No oil conservator, breather, or silica gel — eliminates the need for periodic silica gel replacement, conservator oil-level checks, and breather cleaning. (2) Sealed oil — no moisture ingress or oxidation means oil does not need periodic testing or replacement under normal conditions (recommended oil sample check every 5–10 years for large units, vs. annually for open-breathing types). (3) No sludge/acid formation — insulation degradation is slowed. (4) Installation — arrives factory-filled and tested, so no on-site oil filling, processing, or sampling. (5) Recommended maintenance for the S11: periodic visual inspection of the tank, bushings, and paint; check tightness of bolted connections; verify tap-changer position; clean bushings; and inspect the grounding connection. Because the oil is sealed, there is no routine oil top-up. The expected service life is ≥20 years, with the sealed design extending it by 30–50% over open-breathing designs.
Explore More Transformer & Switchgear Solutions
Complete MV/LV power transformation and distribution solutions from GOHO
SCBH15 Dry Transformer
Amorphous alloy cast-resin dry type.
Learn More
YBM Compact Substation
MV/LV prefabricated substation.
Learn More
GCS Switchgear
Withdrawable LV distribution switchgear.
Learn More
GGD Switchgear
Fixed-type LV main distribution panel.
Learn MoreReliable Sealed Oil-Immersed Distribution Transformer
Tell us your required capacity (30–2500 kVA), primary voltage (10kV or 20kV), secondary voltage (400V or 415V), connection group (Dyn11 or Yyn0), efficiency class (S11/S13/S20/S22), winding material (copper or aluminum), and installation environment. We'll configure the right transformer and provide a factory quote in 24 hours.