HXGN15-12 Switchgear

HXGN15-12 Ring Main Unit | 12kV MV Switchgear | GOHO Electric
HXGN15-12 Ring Main Unit - GOHO Electric
Medium Voltage RMU

HXGN15-12 Ring Main Unit

12kV indoor metal-enclosed ring main unit with SF6 or air-insulated load break switches. Compact design for reliable medium voltage distribution in residential, commercial, and industrial power networks.

12kV Rated 630A Switch IEC 62271 IP2X / IP3X
12kV
Rated Voltage
630A
Rated Current
20kA
Short-Time Withstand
IP2X
Protection

What is HXGN15-12 RMU?

Compact medium voltage ring main unit for distribution automation

HXGN15-12 is an indoor metal-enclosed ring main unit (RMU) designed for 12kV medium voltage power distribution systems. It combines load break switches, circuit breakers, and busbar sections in a compact, fully insulated enclosure, making it ideal for ring network power supply configurations.

Manufactured by GOHO Electric with SF6 or vacuum-insulated switching technology, HXGN15-12 features a modular design with 2-way, 3-way, or 4-way configurations. It is widely used in urban residential areas, commercial buildings, industrial parks, and renewable energy distribution systems.

  • Compact RMU design — all-in-one enclosure saves substation space and reduces installation time
  • SF6 or vacuum switch — choose gas-insulated or vacuum-insulated load break switch technology
  • Fully enclosed — IP2X metal enclosure ensures operator safety and environmental protection
  • Modular configuration — 2/3/4-way combinations with load break switch, breaker, and metering options
  • Smart-ready — compatible with remote monitoring, SCADA, and distribution automation systems
HXGN15-12 RMU interior - GOHO Electric

Detailed Parameters

Complete technical specifications for HXGN15-12 ring main unit

ParameterSpecification
Rated Voltage12kV (also 7.2kV / 10kV available)
Rated Frequency50Hz / 60Hz
Rated Current (Busbar)630A
Rated Current (Feeder)630A / 1250A
Rated Short-Time Withstand20kA (4s)
Rated Peak Withstand50kA
Switch TypeSF6 Load Break Switch / Vacuum Load Break Switch
Breaking Capacity (LBS)630A (load current), 20kA (making current)
Protection GradeIP2X (main circuit compartment)
Insulation LevelLI 75kV / AC 35kV (1 min)
Standard ComplianceIEC 62271-200, GB 3906
Operation ModesManual / Motorized / Remote (SCADA)
Ambient Temperature-25°C to +40°C
Altitude≤ 1000m (above 1000m: derated)

Why Choose HXGN15-12 RMU

Reliable medium voltage ring main unit for modern distribution networks

Compact Design

Modular all-in-one structure with small footprint — fits standard kiosk substations and indoor switch rooms.

Fully Enclosed Safety

Metal-enclosed compartments with IP2X protection — prevents accidental contact with live parts.

Flexible Config

2-way, 3-way, or 4-way ring configurations with mix of LBS, breaker, and metering modules.

Fast Switching

Load break switch provides reliable on-load switching with spring mechanism for consistent performance.

Smart Ready

Compatible with remote monitoring, FTU/DTU terminals, and SCADA for distribution automation.

Low Maintenance

Sealed switch mechanism requires minimal maintenance. 10,000+ mechanical operations guaranteed.

Where HXGN15-12 is Used

Primary medium voltage distribution in urban and industrial networks

Residential Areas

Community substations and residential power distribution

Commercial Buildings

Shopping malls, offices, and mixed-use complexes

Industrial Parks

Factory power distribution and plant substation

Renewable Energy

Solar farms and wind power grid connection

Quality & Compliance

Tested and certified for medium voltage applications

IEC 62271

MV switchgear standard

CCC / CQC

China Compulsory Certification

ISO 9001

Quality management system

Type Tested

Full dielectric & thermal testing

Frequently Asked Questions

Common questions about HXGN15-12 ring main units

What is the difference between RMU and regular switchgear?

A Ring Main Unit (RMU) is a compact, pre-assembled switchgear designed specifically for ring-type distribution networks. Unlike larger switchgear panels that are built from individual components, an RMU integrates two or more load break switches and busbars in a single factory-sealed enclosure. HXGN15-12 is designed for ring networks where power flows in a loop, allowing any section to be isolated without interrupting the rest of the network — perfect for improving distribution reliability.

SF6 vs air/vacuum insulated — which should I choose?

SF6-insulated RMUs use sulfur hexafluoride gas as the arc-quenching and insulation medium — they are more compact and require less maintenance but have higher environmental impact. Vacuum-insulated (air-insulated) RMUs use vacuum interrupters in an air environment — they are more environmentally friendly and typically have a longer service life but may be slightly larger. For most standard applications, both work well. GOHO offers both types — we'll recommend based on your space constraints, environmental policies, and maintenance preferences.

How many ways (feeders) can the HXGN15-12 have?

HXGN15-12 is modular and can be configured with 2 to 6 ways depending on your network requirements. The most common configurations are 2-way (incoming + outgoing) and 3-way (ring-in, ring-out, and transformer feeder). Each way can be equipped with a load break switch, circuit breaker, or fused switch. We also offer metering compartments and protection relay bays. Tell us your single-line diagram and we'll design the exact configuration.

Can HXGN15-12 be used for automatic network reconfiguration?

Yes, HXGN15-12 can be equipped with motorized operation mechanisms and FTU (Feeder Terminal Unit) controllers for automatic fault detection, isolation, and network reconfiguration. This enables self-healing ring networks where power is automatically restored within seconds after a fault. The system can be integrated with your existing SCADA or distribution automation platform using standard communication protocols like IEC 61850, Modbus, or DNP3.

What is the typical lead time for HXGN15-12 RMU?

Standard 2-way and 3-way HXGN15-12 units typically ship within 15-20 working days from order confirmation. Custom configurations with special protection relays, metering, or automation features may take 25-30 working days. All units undergo full factory testing including dielectric withstand test, partial discharge measurement, and mechanical operation tests before shipment. We can also arrange third-party inspection upon request.

Design Your RMU System

Share your single-line diagram and requirements — our engineers will design the optimal HXGN15-12 configuration for your network.

Scroll to Top