PZ30 Series Terminal Distribution Box
PZ30 series distribution box adopts a flame-retardant plastic front panel with a cold-rolled steel enclosure body, combining aesthetic appearance with practical functionality. The insulated, corrosion-resistant plastic panel blends with indoor décor, while the steel body ensures mechanical strength and secure component mounting. With 6–24 DIN-rail module positions, pre-installed N and PE terminal bars, and flush or surface mounting options, the PZ30 is the ideal final distribution board for residential apartments, houses, and small commercial premises.
Compact Final Distribution for Homes & Small Businesses
Plastic-panel, steel-body terminal box with pre-installed N/PE bars and DIN-rail modules
PZ30 series distribution box adopts a plastic panel front cover with a cold-rolled steel sheet enclosure body, combining aesthetic appearance with practical functionality. The plastic panel provides an insulated, corrosion-resistant, and easily cleanable surface that blends well with indoor decorative environments, while the steel box body ensures mechanical strength and secure mounting of internal components.
The panel design facilitates quick disassembly and reassembly for wiring access during installation and maintenance without requiring complete removal of the enclosure. An integrated neutral (N) terminal bar and protective earth (PE) terminal bar are pre-installed inside the enclosure to simplify household wiring installation — providing dedicated connection points for phase, neutral, and earth conductors in compliance with low voltage wiring regulations.
Additional outgoing circuit positions and DIN rail mounting are provided for miniature circuit breakers (MCBs), residual current circuit breakers (RCBOs), and other modular DIN-rail mounted devices. Available in 6 to 24 module configurations, the PZ30 supports everything from a small apartment (6–10 modules) to a large residence or small office (18–24 modules), with flush (recessed) or surface mounting to suit new-build or retrofit installations.
- 220V/380V/400V — 63A/100A main busbar
- 6–24 modules — DIN-rail EN 60715, MCB/RCBO ready
- Pre-installed N & PE bars — dedicated terminal points
- Plastic + steel — insulated panel, robust body
- Flush or surface mount — new-build & retrofit
- IP30/IP40 indoor — 6kA/10kA breaking capacity

Detailed Parameters
Complete technical specifications for PZ30 series terminal distribution box
| Parameter | Specification |
|---|---|
| Rated Voltage | AC 220V / 380V / 400V |
| Rated Frequency | 50Hz / 60Hz |
| Rated Current (Main Busbar) | 63A / 100A (selectable by model) |
| Rated Short-circuit Capacity | 6kA / 10kA (per IEC 60898) |
| Number of Modules | 6 / 10 / 14 / 18 / 24 positions (selectable) |
| Device Mounting | DIN rail (EN 60715) — standard modular devices |
| Incoming Device | Main switch (MCCB or isolating switch) — up to 100A |
| Outgoing Device Type | MCB (Type B/C/D) / RCBO / RCCB / DIN-rail contactor |
| Neutral Busbar | Pre-installed N terminal bar with multiple connection points |
| Earth Busbar | Pre-installed PE terminal bar with multiple connection points |
| Panel Material | Engineering plastic (flame-retardant, UV-stabilized, VO-rated) |
| Box Material | Cold-rolled steel sheet with anti-corrosion coating |
| Degree of Protection | IP30 / IP40 (indoor) |
| Installation Type | Flush-mounting (recessed) / Surface-mounting (optional) |
| Door Type | Solid or transparent cover (selectable) |
| Cable Entry | Top/bottom knock-out openings with entry glands |
| Busbar Material | Tin-plated copper or brass (N & PE) |
| Insulation Voltage (Ui) | 400V |
| Pollution Degree | 2 |
| Operating Temperature | -5°C to +40°C |
| Ambient Humidity | ≤ 95% (non-condensing) |
| Altitude | ≤ 2000m |
| Panel Color | White / off-white (customizable) |
| Standards | GB/T 7251, IEC 61439, IEC 60898 |
Why Choose PZ30 Distribution Box
Aesthetic, safe, and easy-to-install terminal distribution for residential & light commercial
Plastic Panel + Steel Enclosure
The combination of a flame-retardant plastic front panel and cold-rolled steel box body provides electrical insulation at the operator interface while maintaining robust mechanical protection for internal components — the clean white or off-white panel finish blends discreetly with residential indoor wall surfaces, requiring no additional decoration or framing after installation.
Pre-Installed N & PE Bars
Dedicated N and PE terminal bars with multiple connection points are pre-installed at the factory, eliminating the need for on-site assembly of distribution busbars and ensuring proper separation of neutral and protective earth conductors in compliance with TN-S or TN-C-S earthing system wiring rules — reducing installation time and wiring errors.
Standard DIN Rail Mounting
All outgoing devices mount on standard EN 60715 DIN rails, enabling rapid installation of a wide range of standardized modular devices including MCBs (Types B/C/D), RCBOs, RCCBs, DIN-rail contactors, surge protective devices (SPDs), and timers — all available from multiple manufacturers with identical mounting dimensions.
Flexible Circuit Configuration
Available in 6 to 24 module configurations, accommodating from 2 to 12+ single-pole MCB circuits (each single-pole MCB occupies 1 module) plus the incoming main switch — suitable for small apartments (6–10 modules) to large residences or small offices (18–24 modules), selectable to match the exact circuit count required.
Easy Installation & Wiring
The removable panel provides unobstructed access to all DIN-rail mounted devices and terminal bars — knock-out cable entries at top and bottom of the enclosure accommodate incoming and outgoing cables with standard conduit or cable gland fittings, simplifying installation for electrical contractors and allowing wiring to be completed before the panel is fitted.
Flush or Surface Mounting
Standard design supports flush mounting (recessed into wall cavity for a clean, flush finish) for new-build installations, or surface mounting with optional extension frame for retrofit applications where wall chasing is not practical — allowing the same product to be used in both new construction and renovation projects.
IP30/IP40 Indoor Protection
Suitable for indoor installation in residential electrical closets, corridors, utility rooms, and commercial office areas — protection against entry of solid objects greater than 2.5mm (IP30) or 1.0mm (IP40) and against splashing water (IP40 with cover closed), ensuring safe operation in normal indoor environments.
Flame-Retardant Panel
The front panel is manufactured from flame-retardant, UV-stabilized engineering plastic rated UL94 V-0 — in the event of an internal electrical fault or fire, the panel will not sustain combustion and self-extinguishes, protecting the surrounding building fabric and occupants from fire spread.
Optional Transparent Cover
A transparent polycarbonate cover option allows visual inspection of MCB trip status and circuit energization indicators without opening the enclosure — ideal for commercial installations where facility managers need to quickly identify tripped circuits, while maintaining IP-rated protection and lockable security when fitted with a locking latch.
Where PZ30 Distribution Box Excels
Final circuit distribution for residential, commercial, and institutional spaces
Residential Homes
Apartment & house final distribution board
Commercial Offices
Small office lighting & power
Retail Shops
Outlet lighting & power circuits
Education
School room-level distribution
Lighting Control
Individual circuit lighting distribution
Kitchen & Utility
Commercial kitchen power distribution
Renovation
Fuse board replacement & retrofit
Sub-Distribution
Remote area power distribution
Quality & Compliance
Certified for safe residential and commercial final distribution
IEC 61439
Low-voltage switchgear assemblies
GB/T 7251
LV complete switchgear standard
UL94 V-0
Flame-retardant plastic panel
ISO 9001
Quality management certified
Frequently Asked Questions
Common questions about PZ30 terminal distribution boxes
The module size you need depends on the total number of DIN-rail devices in your installation. Each single-pole MCB occupies 1 module (17.5mm wide); a double-pole device or RCBO occupies 2 modules; a 3-pole MCCB occupies 3 modules. To calculate the required size, count: (1) the main incoming switch (usually 2 modules for a double-pole isolator or MCCB in single-phase, or 3 modules for a 3-pole device in three-phase), (2) all outgoing MCBs and RCBOs (1 or 2 modules each), and (3) any optional devices such as surge protectors (SPDs), timers, or DIN-rail contactors. Add 10–20% spare capacity for future circuit additions. PZ30 sizes available: 6, 10, 14, 18, and 24 modules. As a rough guide: a small studio or one-bedroom apartment typically needs 6–10 modules; a standard 3-bedroom house needs 14–18 modules; a large house or small office with many circuits needs 18–24 modules. Always consult a qualified electrician to determine the exact module count based on your electrical design.
Flush mounting (also called recessed mounting) means the steel box body is embedded into a cavity in the wall, with only the plastic front panel sitting flush with the wall surface. This gives a clean, unobtrusive finish and is the standard choice for new-build installations where wall cavities are accessible during construction. The wall opening must be sized to match the box dimensions. Surface mounting means the entire box is mounted on the surface of the wall, with an optional surface-mount frame or plinth to provide cable access from the rear. Surface mounting is used in retrofit or renovation projects where chasing the wall is impractical, in concrete or solid-wall buildings, or in industrial premises where the box must remain accessible. Both mounting methods provide the same electrical performance; the choice is purely aesthetic and practical. When ordering, specify "flush" or "surface" and, for surface mounting, whether you need the optional surface-mount frame.
The MCB trip curve determines the instantaneous tripping current and should be matched to the load type: (1) Type B — trips between 3 and 5 times the rated current. Suitable for purely resistive loads such as lighting circuits, socket outlets, and general domestic power. This is the most common choice for residential installations. (2) Type C — trips between 5 and 10 times the rated current. Suitable for inductive loads with moderate inrush current such as fluorescent lighting, small motors, and commercial equipment. Type C is commonly used in commercial and industrial installations. (3) Type D — trips between 10 and 20 times the rated current. Suitable for highly inductive loads with high inrush current such as large motors, transformers, and X-ray equipment. Using the wrong trip curve can cause nuisance tripping (if the curve is too sensitive for the load) or delayed protection (if too insensitive). For residential PZ30 boards, Type B is standard for most circuits; Type C may be required for circuits supplying motors or fluorescent lighting banks. Always follow the electrical design and local wiring regulations.
Both approaches provide earth-leakage (residual current) protection and overcurrent protection, but they differ in configuration and module usage: (1) RCBO (Residual Current Circuit Breaker with Overcurrent protection) — a single device that combines RCCB and MCB functions in one unit, occupying 1 or 2 modules per circuit. It provides individual earth-leakage protection for each circuit, meaning a fault on one circuit trips only that circuit, leaving others energized. RCBOs are more expensive per circuit but offer better discrimination and use less wiring. (2) Separate RCCB + MCB — one upstream RCCB (typically 2 modules) protects a group of downstream MCB circuits. This is more cost-effective for multiple circuits but means a fault on any one circuit trips the entire group. Many PZ30 installations use a split-load arrangement: one RCCB protecting the power/socket circuits and another RCCB protecting the lighting circuits, with individual MCBs for each final circuit. For circuits requiring individual protection (e.g., wet areas, outdoor sockets, or critical equipment), an RCBO is preferred. Your electrician should determine the optimal arrangement based on the circuit layout and local regulations.
Yes, the PZ30 can be configured for three-phase (380V/400V) installations. For three-phase, the main incoming switch is a 3-pole or 4-pole MCCB (occupying 3 or 4 modules), and outgoing 3-pole MCBs are used for three-phase loads (e.g., motors, three-phase sockets), while single-pole MCBs distribute each phase to single-phase circuits. The pre-installed N and PE terminal bars provide the required neutral and earth connections for both three-phase and single-phase circuits. For three-phase installations, a larger module size (typically 14 modules or above) is usually required to accommodate the 3-pole main switch and the additional single-pole circuits across three phases. Ensure the main busbar and terminal bars are rated for the three-phase fault current. For higher-current three-phase installations above 100A, consider the XL-21 or GGD cabinet instead of the PZ30, as the PZ30 is limited to 63A/100A main incoming current.
The PZ30 and GHM are both low voltage distribution boxes, but they target different applications: (1) PZ30 — a compact terminal distribution box with a plastic front panel and steel body, designed for final circuit distribution in residential and small commercial premises. It uses DIN-rail mounted MCBs/RCBOs only, has a maximum main current of 100A, 6–24 modules, and is typically flush-mounted into walls. Its primary role is the final consumer unit or fuse board. (2) GHM — a more industrial distribution box available in IP30/IP40/IP54 ratings, supporting up to 630A main busbar and accommodating MCCBs, contactors, relays, and control transformers in addition to MCBs. It is wall-mounted or floor-standing and used for sub-main distribution, small motor control, and commercial/industrial applications where higher currents or control components are needed. In a building's distribution hierarchy, the GHM (or XL-21) acts as a sub-main board feeding multiple PZ30 final distribution boards on each floor or in each apartment. Choose PZ30 for final consumer circuits up to 100A, and GHM for sub-main or light industrial applications up to 630A.
Explore More Distribution Solutions
Complete range of LV distribution, metering, and switchgear products from GOHO

GHM Distribution Box
Modular DIN-rail LV distribution up to 630A.
Learn More
GHBX Metering Box
Single-phase revenue metering enclosure.
Learn More
XL-21 Power Cabinet
Floor-standing LV cabinet up to 1000A.
Learn More
YBM Compact Substation
Complete MV/LV substation with LV bay.
Learn MoreSafe Final Distribution for Every Premise
Tell us your circuit count, single-phase or three-phase, and mounting type (flush or surface). We'll recommend the right PZ30 module size, MCB/RCBO configuration, and N/PE arrangement with a factory quote in 24 hours.