JXF-2000 series of Jiye box

JXF-2000 Jiye Enclosure Junction Box | 400V/690V, IP65, up to 250A | GOHO
GOHO JXF-2000 Jiye enclosure junction box
Jiye Enclosure / Junction Box

JXF-2000 Series Jiye Enclosure

JXF-2000 type Jiye box is an electrical junction and control enclosure divided into indoor wall-mounted control boxes and outdoor weatherproof protection boxes. The outdoor protection box is available in two door configurations: solid metal door and transparent perspective door with an impact-resistant viewing window. All products are manufactured from high-quality electrolytic cold-rolled steel plate with epoxy resin electrostatic spraying, featuring pre-punched top and bottom cable knock-outs, a detachable galvanized internal mounting plate, and factory-sealed openings — rated up to IP65 for dependable outdoor service.

400V / 690V Up to 250A IP65 Outdoor Top & Bottom Entry
690V
Max Rated Voltage
250A
Max Rated Current
IP65
Max Outdoor Protection
1.2–1.5mm
Sheet Metal Thickness

Higher Voltage, Higher IP Rating, Factory-Sealed Junction Enclosure

400V/690V, IP65 outdoor, top & bottom entry, detachable galvanized mounting plate

JXF-2000 type Jiye box is divided into indoor wall-mounted control boxes and outdoor weatherproof protection boxes. The outdoor protection box is available in two door configurations: solid metal door and transparent perspective door (with impact-resistant viewing window). All products are manufactured from high-quality electrolytic cold-rolled steel plate, with the surface treated through epoxy resin electrostatic spraying, providing a beautiful and durable finish with excellent corrosion resistance and uniform coating coverage.

The enclosure is equipped with pre-punched upper and lower cable entry/exit knock-out openings and a detachable internal mounting base plate for component installation. All inlet and outlet openings are sealed at the factory with protective plugs or sealing plates to maintain enclosure integrity during transport and storage, and are removed only for cable entry during on-site installation.

With selectable rated voltage of 400V or 690V AC and current ratings from 63A up to 250A, plus IP54/IP65 outdoor and IP43 indoor protection via a V-shaped drip-edge seal, the JXF-2000 is a versatile industrial-grade junction and control enclosure suitable for electrical control and distribution, industrial automation junction and terminal boxes, commercial building services, outdoor equipment protection, telecommunications, infrastructure, and agricultural electrification.

  • 400V / 690V AC — selectable by configuration
  • 63A / 100A / 160A / 250A — selectable by model
  • IP54/IP65 outdoor / IP43 indoor
  • Top & bottom knock-outs — flexible cable routing
  • Detachable galvanized plate — bench assembly, then fit
  • Factory-sealed openings — plugs removed on-site only
JXF-2000 Jiye junction box with V-shaped drip-edge seal

Detailed Parameters

Complete technical specifications for JXF-2000 Jiye enclosure

ParameterSpecification
Rated VoltageAC 400V / 690V (selectable by configuration)
Rated Frequency50Hz / 60Hz
Rated Current63A / 100A / 160A / 250A (selectable by model)
Enclosure MaterialElectrolytic cold-rolled steel plate
Surface TreatmentEpoxy resin electrostatic spraying — min. 60μm
Degree of Protection (Outdoor)IP54 / IP65
Degree of Protection (Indoor)IP43
Door Type (Outdoor)Solid metal door or transparent perspective door
Door Type (Indoor)Solid metal door
Gasket SealingSealing rubber strip on V-shaped drip-edge box edge
Cable EntryPre-punched top and bottom knock-out openings
Mounting BaseDetachable internal mounting plate (galvanized steel)
Factory SealingAll entry/exit openings sealed at factory with protective plugs
Installation TypeIndoor wall-mounted / Outdoor wall-mounted
Enclosure Thickness1.2mm – 1.5mm (sheet metal)
Insulation Voltage (Ui)690V (for 690V configuration)
Impulse Withstand Voltage (Uimp)6kV / 8kV (configuration dependent)
Pollution Degree2 / 3
Operating Temperature-25°C to +40°C
Storage Temperature-40°C to +70°C
Ambient Humidity≤ 95% (non-condensing)
Altitude≤ 2000m
Coating ColorLight grey / white (customizable)
StandardsGB/T 7251, IEC 61439

Why Choose JXF-2000 Jiye Enclosure

Industrial-grade junction box with 690V rating, IP65 sealing, and factory-ready cable entry

Dual Configuration Options

Available in both indoor wall-mounted control box and outdoor weatherproof protection box configurations, providing application flexibility for different installation environments — outdoor units are constructed with additional weather sealing and UV-resistant coating for reliable long-term outdoor service, while indoor units offer a cost-effective solution for protected locations.

Transparent Perspective Door

The outdoor protection box can be specified with a transparent perspective door fitted with an impact-resistant polycarbonate or tempered glass window, allowing visual inspection of internal components, indicators, and meters without opening the enclosure — maintaining weather protection while enabling convenient equipment status monitoring.

High-Quality Steel Construction

Manufactured from electrolytic cold-rolled steel plate with epoxy resin electrostatic spraying, the enclosure provides excellent mechanical impact resistance, corrosion protection, and uniform coating coverage on all surfaces including edges and corners — significantly outperforming conventional spray-painted enclosures in coating adhesion and long-term durability.

V-Shaped Drip-Edge Seal

The box opening is formed with a V-shaped drip-edge profile with a fitted sealing rubber strip, preventing rainwater ingress when the door is closed while maintaining effective sealing even after repeated door opening and closing cycles — critical for outdoor installations exposed to wind-driven rain and achieving IP54/IP65 protection.

Pre-Punched Top & Bottom Entry

Upper and lower cable entry/exit knock-out openings are positioned for convenient top-entry and bottom-entry cable routing, accommodating standard conduit or cable gland sizes — all openings are factory-sealed with protective plugs that are easily removed during installation, giving flexibility for either overhead or underground cable runs.

Detachable Galvanized Mounting Base

An internal mounting plate is supplied with each enclosure, which can be removed for external component assembly on a workbench before being installed back into the enclosure — significantly improving installation efficiency and build quality by allowing pre-wiring of DIN-rail components, terminal blocks, and control devices outside the confined enclosure space.

Factory-Sealed Openings

All entry points are sealed at the factory to prevent entry of dust, moisture, and debris during transport, handling, and storage — only the required openings are unsealed during on-site installation, maintaining maximum enclosure integrity and ensuring the IP rating is not compromised before the enclosure is commissioned.

690V High-Voltage Rating

Unlike standard 400V junction boxes, the JXF-2000 supports a selectable 690V AC rated voltage, making it suitable for industrial and infrastructure applications where 690V distribution systems are used (e.g., large motor drives, renewable energy plants, heavy industry) — a single enclosure family that covers both 400V commercial and 690V industrial installations.

IP65 Outdoor Protection

With IP54/IP65 outdoor protection and IP43 indoor protection, the JXF-2000 offers a higher ingress rating than many competing junction boxes — IP65 provides full dust protection and protection against water jets from any direction, making it suitable for exposed outdoor locations, wash-down areas, and dusty industrial environments where lesser-rated enclosures would fail.

Where JXF-2000 Jiye Enclosure Excels

Industrial-grade junction & control enclosure for demanding environments

Electrical Control & Distribution

Indoor & outdoor control panels

Industrial Automation

Junction & terminal boxes for field devices

Commercial Building Services

Lighting control & power distribution

Outdoor Equipment Protection

Pumps, valves & instrumentation

Telecommunications

Networking equipment enclosures

Infrastructure

Traffic control & street lighting

Public Facilities

Outdoor electrical enclosures

Rural Electrification

Agricultural equipment housing

Quality & Compliance

Certified for indoor and outdoor industrial enclosures

IEC 61439

Low-voltage switchgear assemblies

GB/T 7251

LV complete switchgear standard

IP65 Rated

Dust-tight & water-jet protected

ISO 9001

Quality management certified

Frequently Asked Questions

Common questions about JXF-2000 Jiye enclosures

What is the difference between JXF-1000 and JXF-2000 Jiye boxes?

Both the JXF-1000 and JXF-2000 are indoor/outdoor Jiye distribution and junction enclosures sharing the same electrolytic steel + epoxy coating platform, but they differ in electrical rating, protection level, and construction details: (1) Voltage — JXF-1000 is rated 400V only; JXF-2000 supports 400V or 690V selectable, suitable for industrial 690V systems. (2) Current — JXF-1000 up to 400A; JXF-2000 offers discrete ratings of 63A/100A/160A/250A (smaller, more junction-oriented). (3) Protection — JXF-1000 IP44/IP54 outdoor; JXF-2000 reaches IP54/IP65 outdoor (higher, dust-tight) and IP43 indoor. (4) Cable entry — JXF-1000 bottom entry only; JXF-2000 has pre-punched top AND bottom knock-outs for overhead or underground routing. (5) Mounting — JXF-2000 adds a detachable galvanized internal mounting plate for bench assembly. (6) Factory sealing — JXF-2000 seals all openings with protective plugs at the factory. Choose JXF-2000 for higher IP, 690V, top/bottom entry, and junction/terminal applications; choose JXF-1000 for higher current (up to 400A) distribution at 400V.

How does the detachable galvanized mounting plate improve installation?

The detachable galvanized internal mounting plate is a key time-saver and quality enhancer: (1) Bench assembly — the plate can be removed from the enclosure and clamped to a workbench, where components (DIN-rail MCBs, contactors, terminal blocks, PLCs) can be mounted and pre-wired in a flat, well-lit, ergonomic position rather than reaching inside a confined box. (2) Better wiring quality — working on a flat surface produces neater, more consistent wiring and easier torque verification on terminals, reducing the risk of loose connections. (3) Galvanized corrosion resistance — the plate is galvanized steel, so it resists corrosion even in humid environments and provides a reliable earth/PE bonding surface. (4) Easy re-installation — the pre-wired plate is simply bolted back into the enclosure, and field cables are terminated to the pre-routed terminals. This approach cuts on-site installation time significantly and is especially valuable for repeat or high-volume panel builds.

Why are the cable knock-outs factory-sealed, and when do I remove the plugs?

All top and bottom cable entry knock-outs are sealed at the factory with protective plugs or sealing plates to: (1) Maintain enclosure integrity during transport, handling, and storage — preventing dust, moisture, insects, and debris from entering before installation. (2) Preserve the IP rating — an unsealed knock-out is an open hole that would completely defeat the IP54/IP65 protection. (3) Allow selective opening — only the knock-outs actually needed for cable entry are opened on-site; the rest remain sealed. On-site procedure: (a) Identify the knock-out locations matching your cable routing (top entry for overhead, bottom entry for underground). (b) Remove the protective plug or punch out the knock-out. (c) Fit an IP-rated cable gland of the correct size and tighten to the specified torque. (d) Verify the seal. Leaving unused knock-outs sealed is essential to maintain the enclosure's protection rating. Never leave an opened knock-out without a gland or blanking plug.

Can the JXF-2000 be used in 690V industrial systems?

Yes. The JXF-2000 is available with a selectable 690V AC rated voltage (Ui up to 690V, Uimp up to 8kV depending on configuration), making it suitable for 690V industrial distribution systems commonly found in: heavy industry, mining, oil & gas, renewable energy plants (wind/solar), and large motor drive installations. When specifying for 690V: (1) Confirm the 690V configuration at ordering so the correct insulation coordination and clearance/creepage distances are applied internally. (2) Ensure all internal components (MCBs, contactors, terminal blocks, busbars) are themselves rated for 690V. (3) For 690V systems with higher fault levels, confirm the short-circuit withstand rating of the internal busbar system matches your prospective fault current. (4) Apply appropriate 690V labeling and warning signage. Do not use a 400V-configured enclosure in a 690V system, as the internal clearances may be insufficient.

What does IP65 mean for outdoor installation, and what is not covered?

IP65 protection means: First digit '6' (dust-tight) — no ingress of dust; complete protection against contact. Second digit '5' (water jets) — protection against water jets (12.5mm nozzle, 12.5 L/min, 30kPa) projected from any direction; limited ingress permitted (no harmful effect). For outdoor installation this means the JXF-2000 IP65 variant can withstand: direct rain, wind-driven rain, water spray from hoses during cleaning, and dusty environments. What IP65 does NOT cover: (1) Temporary or continuous submersion (that requires IP67/IP68). (2) High-pressure water jets (>30kPa, e.g., pressure washers — that requires IP66). (3) Condensation inside due to temperature cycling — ensure adequate internal climate control (heaters, vent plugs) for large temperature swings. (4) UV and corrosion of the exterior coating — the epoxy coating handles normal UV, but extreme coastal or chemical atmospheres may require a higher-grade finish. Always install a canopy for prolonged direct sun/rain exposure and ensure cable glands are IP65-rated.

How do I choose between solid metal door and transparent perspective door?

The door choice depends on whether you need visual access to internal devices: (1) Solid metal door — recommended for general distribution, junction, and control applications where no visual indication is required. It offers the highest mechanical strength and impact resistance, a clean uniform appearance, and the simplest sealing. Choose this for outdoor electrical distribution panels, terminal boxes, and any application where the door is opened only for maintenance. (2) Transparent perspective door (outdoor only) — recommended when you need to read meters, check pilot lights, or inspect component status without opening the enclosure (e.g., metering panels, status-indication control panels, remote/unmanned sites). The window is impact-resistant polycarbonate or tempered glass. Note that the window area has slightly lower impact resistance than solid metal and may need cleaning to maintain visibility. The transparent door still uses the same V-shaped drip-edge seal to maintain IP54/IP65. For indoor models, only the solid metal door is offered since weather sealing is not a concern.

Jiye Enclosure for Junction & Control

Tell us your required voltage (400V or 690V), current rating, IP level, door type (solid or transparent perspective), and cable entry preference (top, bottom, or both). We'll configure the JXF-2000 with the right galvanized mounting plate, factory-sealed knock-outs, and V-shaped seal — with a factory quote in 24 hours.

Scroll to Top